background image

 
 
 

Sleep Mode 

(This mode can only be selected when using the Remote control )  

1)  To set Sleep mode, make sure the unit is in Air Conditioner mode. 

2) Press the 

SLEEP 

Button on the remote control. The “

” icon appears on the control panel display.  

3) When in 

SLEEP 

mode, the fan will run on low to keep fan noise at a minimum.  

4)  When in Air Conditioner mode, the temperature setting will gradually increase to 2

°

F above the original set 

temperature for 6 hours.  After 6 hours the temperature setting will return to the set temperature. 

5)  When in Dehumidifier mode, the temperature will not change when Sleep mode is selected. 
 

 
 

Compressor Indicator 

The “

” icon will light up on the control panel display when the compressor turns on. The “

” icon 

will turn off when the compressor shuts off. 
 

Emergency Condensate Holding Tank 

 

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to 
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency 
condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut 

off and the “ 

” will appear on the control panel display. To empty the condensate tank, pull the drain plug 

at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out 
of the condensate tank. Once the condensate tank is drained, the unit will begin working within a few minutes. 
The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small 
hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into 
a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the 
room temperature is higher than 90

°

F .

 

 
 

 13 

Содержание PE3-12R-03

Страница 1: ...12 000 BTU Portable Air Conditioner PE3 12R 03 Operating Instructions 2010 Soleus Air International Model No PE3 12R 03 3092402...

Страница 2: ...manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual...

Страница 3: ...rating temperature or lower than the minimum operating temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL PE3 12R 03 COOLING CAPACITY 12 000 BTU H DEHUMIDIFYING CAPACITY 60 p...

Страница 4: ...ounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if t...

Страница 5: ...PRODUCT DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment 5 Air Intake Cover Filter...

Страница 6: ...ws and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSES Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and l...

Страница 7: ...DUAL HOSE WINDOW KIT INSTALLATION 7 When using with a sliding door it is recommended to place the air outtake hose above the air intake hose...

Страница 8: ...Screws A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2...

Страница 9: ...t intake cover After installing the hose remove the square air intake cover on the back of the unit and install the square air intake vent with removable washable filter For Single Hose Window Kit Ins...

Страница 10: ...MULTI COLOR DISPLAY POWER BUTTON MODE BUTTON TIMER BUTTONS TEMP TIMER SELECTION FAN SPEED BUTTON AUTO A C DEHUM FAN FAN SPEED TIMER ON TIMER OFF TEMPERATURE AND TIMER INDICATOR OSCILLATION ON OFF SLEE...

Страница 11: ...mperature select between C and F 5 SWING To turn on the exclusive WAVEFLO oscillation press the SWING button on the control panel Once you press SWING the louvers on the unit will oscillate up and dow...

Страница 12: ...g the moisture from the room NOTE The unit will not perform in dehumidifier mode when the room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the uni...

Страница 13: ...the room temperature is low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergenc...

Страница 14: ...ER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED SWING LOUVER OSCILLATION OPERATING THE UNIT USING THE REMOTE CONTROL 14 Remote Colors may...

Страница 15: ...speed label Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner mode you can...

Страница 16: ...ied 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly...

Страница 17: ...appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty serv...

Отзывы: