background image

 

 

10

d) 

Press the Mode Button until the “AUTO” appears on the LCD display. 

e) 

Select the fan speed by using FAN button.  

 

During the AUTO model, the unit operates at heating mode when the room temperature is below 68 
degree.  It operates at dehumidifying mode when the room temperature is between 68 to 80 degree.  It 
operates at cooling mode when the room temperature is above 80 degree.  You may use the timer with the 
AUTO mode. 
 
6) 

Sleep Mode 

 
           a) 

The air conditioner in operation 

b) 

Press SLEEP to enter into sleep mode 

c) 

The fan motor of indoor unit runs in low speed 

d) 

When in cooling mode, within the first two hours, the temperature will be increased 1

 

per hour. Then temperature will be keeping at 2

 higher than the original degree for 6 

hours.6 hours later, temperature will return to original degree you set. 

e) 

When in heating mode, within the first 2 hours, temperature will be decreased 1

 per 

hour. Then temperature will be keeping at 2

 Lower than the original degree for 6 

hours.6 hours later, temperature will return to original degree you set. 

g)        When in dehumidify mode, the temperature will not be changed. 
 

NOTE: When the room temperature is low and the indoor humidity is high, the condensate of the air 
conditioner may not be discharged in time.  Water will accumulate in the unit that leads to the unit stops 
working automatically for a long time. (At the moment, the indicator lamp “WATER FULL” in the LCD 
is light.) In order to let your unit recover working quickly, you can pull out the “Drain Port” which is 
located in the middle and bottom of the back of the unit. The condensate will be discharged several 
minutes after water be drained.

  

Please use at least 1.5 liter pan to catch the dripping water. 

It is not advised to use continuous drain method when the room temperature is higher than 90

 

 

 

OPERATION USING REMOTE CONTROLLER 

 
The remote controller provided with the unit may operate this portable air conditioner.  The remote 
controller uses two - AAA batteries (provided).  Install the batteries before using the remote controller. 
 
 

REMOTE CONTROLLER  

 

You may use the remote controller to do all the operations.  You can only turn on or off the swing 
operation from the remote controller. 
 
The LTD displays on remote controller either in Celsius or Fahrenheit.  Press + and -  keys 
simultaneously to change the display from Celsius to Fahrenheit or vice verse.  

Содержание MAC-10K

Страница 1: ...Cooling Heating Dehumidifying Fan Please read this owner s Manual carefully before operating the unit...

Страница 2: ...PARTS 3 INSTALLATION BEFORE USE 4 CONTROL PANEL AND LCD DISPLAY 5 CONTROL PANEL FUNCTIONS 6 OPERATION USING CONTROL PANEL 7 OPERATION USING REMOTE CONTROLLER 9 MAINTENANCE 9 TECHNICAL SPECIFICATIONS 1...

Страница 3: ...utomatically returns to the original setting after a power outage IMPORTANT SAFEGUARDS Before you use your portable air conditioner please read this operation manual carefully 1 Never use or store gas...

Страница 4: ...NAMES OF PARTS 4...

Страница 5: ...5 Exhaust Duct Window Kits INSTALLATION BEFORE USE 1 Exhaust Duct...

Страница 6: ...e window or the sliding door Use all three panels if necessary Cut the window piece as needed to fit the length of your window or sliding door Make sure that both holes on the main piece are not cover...

Страница 7: ...NEL LCD DISPLAY Control Panel Functions 1 Power On Off Control Starts or Stops the Unit 2 Mode Control Select the functions of the unit for Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mo...

Страница 8: ...t time in a constant mode To program the timer press Select key until the LCD display shows a flashing on Pressing either or Temperature Time keys to change the clock to the desired time for the unit...

Страница 9: ...an 61 degree 3 Fan Operation a Plug the Power Cord to the power outlet b Turn on the unit by pressing the On Off Button on the control panel c Press the Mode Button until FAN appears on the LCD displa...

Страница 10: ...temperature will not be changed NOTE When the room temperature is low and the indoor humidity is high the condensate of the air conditioner may not be discharged in time Water will accumulate in the u...

Страница 11: ...tly into warm about 104 F water with a neutral detergent Rinse the filter and dry it thoroughly in a shaded place c Replace the filter back to the filter compartment after it is thoroughly dried a If...

Страница 12: ...NSIONS PACKAGE 20x35x23 Inch 20x35x23 Inch REFRIGERANT R22 R22 NOTE 1 The above cooling capacity is measured at ambient temperature of DB 86 F WB 78 F 2 Noise level is measured at the point where is 3...

Страница 13: ...CONTACT INFORMATION Contact For Optional and Spare Parts Technical Support Warranty Claim Customer Service Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA 888 8 SOLEUS www soleusair c...

Страница 14: ...ER 1 Damage accidental or other wise to the air conditioner while in the possession of a consumer not caused by a defect in material or workmanship 2 Damage caused by consumer misuse tampering or fail...

Страница 15: ...15...

Отзывы: