USING YOUR AIR CONDITIONER 

Electronic Control Panel & Remote Control 

 

 

 

 

1. 

Power Button: 

Turns the air conditioner on and 

off

.

 

2. 

Digital Display: 

Under ON status without timer

setting,the operation mode is Cool, Energy 

Saver

or Dry mode,

 

and the set temperature will be

displayed.

Under ON status without timer setting, the 

opera-

tion mode is 

F

an mode and the

 room temperature

 

will be displayed

.  

Time will be displaye

d

 under timer setting or timer

preview

 

 

3. 

Temperature Set: 

Use these buttons on the con-

trol panel and remote to increase or decrease the 
Set Temperature (the desired room temperature) 
in cooling

,

energy saver 

and dry 

mode. 

4. 

Timer Set: 

Use these buttons on the control 

panel and remote to set the Timer. Each press of 
the 

          

 buttons will increase or de

crease the

timer. For timer instructions see #7. 

5. 

Fan Speed

: Use the fan speed but

ton to change

the fan speed. Choose between 

low, medium,

and

 high. 

                                      

6. 

Mode Button: 

Press the mode button to cycle 

through the various modes:

 

Energy

 Saver, Dry

 

(Dehumidifier)

, Fan and Cool

7.

  Auto-on Timer: 

When the air conditioner is off, it 

can be set to automatically turn on in 

1

-24 hours 

at the previous set mode and fan setting. To set 
the Auto-on Timer, press the 

TIMER 

button on th

e

unit or remote control. 

The timer can be set in 

1

 

The

 hour indicator on the bottom right of the dig-

 

Auto-off Timer: 

When the air conditioner is on, it 

can be set to automatically turn off in

 1

-24

 hours.

 

To se

t

 the Auto-off Timer, press the 

TIMER 

button on the unit or remote control. 

The timer 

 

can be set in 

1

 hour increment

.

The 

hour indicator on the bottom right of the dig-

 

• 

To see the remaining time, press the 

TIMER 

Button. To change the timer setting use the 

/

 on the unit or the +/- buttons on the 

remote. 

• 

   

During preview of timer or timer setting,

press Timer button on the panel or remote 

8. 

Filter 

Reset

After the fan rotates for 250 total 

hours, the filter check light will turn on to remind 
the user to clean the filter. Press the Filter 

Reset

 

button once the filter is cleaned to reset the re-
minder.

 

NOTE: This display always shows the room temperature

 in Fan 

 

Mode 

except when setting the Set temperature or the Timer

 

 

Normal Operating Sounds 

• 

You may hear a pinging noise caused by water 
hitting the condenser, on rainy days, or when the 
humidity is high. This design feature helps re-
move moisture and improve efficiency.  

• 

You may hear the thermostat click when the com-
pressor cycles on and off. 

• 

Water will collect in the base pan during rain or 
days of high humidity. The water may overflow 
and drip from the outside part of the unit. 

• 

The fan may run even when the compressor is 
not on. 

hour increment

.

controller to cancel the timer setting.

 

9

 

/

 

 

ital display will start flashing.

 

 

 

ital display will start flashing.

 

 

 

To  switch between Celsius/Fahrenheit

 

display,

press the           button

s

 at the same time

/

 

 

 

    

Point the remote control at the 

air conditioner when sending instruction

 to the

 

unit

.

 

9

.

 

  Signal Receiver

:

Содержание HCC-W08ES-A1

Страница 1: ...Model HCC W08ES A1 HCC W10ES A1 Electronic Window Air Conditioner Operating Instructions...

Страница 2: ...owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in thi...

Страница 3: ...nd or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Pre...

Страница 4: ...ir Conditioner 1 Remote Control 1 AAA Batteries 2 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Accordion Panels 2 Sash Lock 2 Foam Seal 1 Long Screw for Window Locking Bracket Accordion Panels 12...

Страница 5: ...D INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 4 Model HCC W08ES A1 HCC W10ES A1 Power Supply Ph V Hz 1 115 60 1 115 60 Rated Cooling Capacity BTU h 8 000 10 000 Coo...

Страница 6: ...The Lower Sash the lower part of the window that moves up and down must allow for 14 5 368mm of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or me...

Страница 7: ...tion and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the top of the outer case using four Short Screws 6 m o u n t i n g r a i l T...

Страница 8: ...install the accordion panels on each side 1 Place the air conditioner on a hard flat surface 2 Locate the accordion panels in the box 3 Insert the side curtains into the upper and lower rails of the...

Страница 9: ...emoving the Air Conditioner from the Window 1 Turn the air conditioner off and disconnect the power cord 2 Remove the sash seal from between windows and unscrew sash lock 3 Remove the screws installed...

Страница 10: ...is on it can be set to automatically turn off in 1 24 hours To set the Auto off Timer press the TIMER button on the unit or remote control The timer can be set in 1 hour increment The hour indicator...

Страница 11: ...Press the or button to set the timer within 1 24 hours To cancel the timer press the TIMER button again Press the TIMER button when the unit is on to set up the Auto off timer The hour indicator on th...

Страница 12: ...Quieter Nighttime Cooling Set the Mode to Cool and the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if tur...

Страница 13: ...ar To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping C...

Страница 14: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 15: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 16: ...rmal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus Home Comfort maintains a centralized service network to provide parts and assist in resolving service proble...

Отзывы: