8
1. Route a copper with ground, supply wiring with minimum #12AWG for 13500 BTU/H unit. The wiring
from its power source to the electric box. Do not attach them at this time.
ELECTRIC WIRING
Make sure that all power supply to the unit is disconnected before starting any work on the unit to avoid the possibil-
ity of shock or injury and/or damage to the equipment. After the interior ceiling assembly frame is properly secured
to the Roof Top Air Conditioner, the following electrical connections must be performed.
3. Connect Roof Top Air Conditioner power
cord to the side of the Electric Box (see Fig-
ure 2).
4. Insert the power cord #12AWG to the other
end of the Electric box (see Figure 2).
5. Connect the power supply cord (#12AWG) to the Black, White, and Green/
Ground wires in Electric Box with a terminal board. Connect Black wire to Black
wire, White wire to White wire, and Green/Ground wire to YE/GN wire (see Figure
2).
6. Tighten the relief clamp screws to secure the supply power cord, make sure DO
NOT OVERTIGHTEN. Reinstall the Electric Box cover (see Figure 2).
2. Unscrew 2 screws and remove the Electric
Box cover (see Figure 1).