OPERATING YOUR AIR CONDITIONER 

REMOTE CONTROL 

Battery Size: AAA - NOTE: Do not mix old and new batteries or different types of AAA batteries. 

1. 

ON/OFF 

- Press the ON/OFF button to turn 

the A/C on or off. When the unit is turned off, 
the Timer and sleep functions will be can-
celled. The set temperature will be saved. 

2. MODE 

- Press the MODE button to change 

the operating mode. You can choose AUTO, 
COOL, SAVE (energy saver), FAN only, or 
Dry (Dehumidifier). The temperature will not 
be displayed when AUTO mode is selected.

 

3. 

“—”- 

Press the “-” button to decrease the 

temperature when the unit is on. Press and 
hold the “-” button for more than 2 seconds to 
quickly  cycle through the temperature op-
tions. Stop pressing the button when the de-
sired temperature is displayed. The tempera-
ture cannot be set in auto mode. Temperature 
range: 61°F - 86°F. 

4. “+” 

Press the “+” button to increase the 

temperature when the unit is on. Press and 
hold the “+” button for more than 2 seconds to 
quickly cycle through the temperature op-
tions. Stop pressing the button when the de-
sired temperature is displayed. The tempera-
ture cannot be set in auto mode. Temperature 
range: 61°F - 86°F.

 

5. 

FAN 

- Press the FAN button to turn change 

the FAN options. You can choose between 
four speeds and auto mode. The fourth fan 
option is only available in cooling and energy 
saver modes.   

6. IFEEL 

MODE 

- Press the IFEEL button to 

change the thermostat sensor from the air 
conditioner to the remote location. The air con-
ditioner will cool the area depending on the 
location and set temperature of the remote 
control. Take the remote control with you so 
the air conditioner cools the room to your loca-
tion. The Remote must be in line of site of the 
A/C for iFeel to operate correctly.

 

7. 

SLEEP MODE 

- Press the SLEEP button to 

turn SLEEP mode on or off. SLEEP mode is 
set to off automatically. When SLEEP mode is 
selected the timer can be adjusted. SLEEP 
mode is not available in Fan or Auto mode. 
Sleep mode automatically reduces set tem-
perature by 2°F after one hour and 4°F after 
two hours. This feature limits compressor us-
age and in turn enhances energy saving while 
you are sleeping.

 

 

8. 

TIMER - 

Press the TIMER button when the 

unit is off to set up the Auto-on timer. The Auto
-on time can be set between .5 - 24 hours. The 
icons “T-ON” and “H” will flash for 5 seconds. 
Start selecting the time using the “+” and “-” 
buttons before the icons stop flashing. The 
time will increase/decrease in .5 hour incre-
ments with each press of the “+” or “-” buttons.  
To cancel the Auto-on time, manually press 
the ON/OFF button to turn the unit on. 

 

Press the TIMER button when the unit is on to 
set up the Auto-off timer. The Auto-off time can 
be set between .5 - 24 hours. The icons “T-
OFF” and “H” will flash for 5 seconds. Start 
selecting the time using the “+” and “-” buttons 
before the icons stop flashing. The time will 
increase/decrease in .5 hour increments with 
each press of the “+” or “-” buttons.  To cancel 
the Auto-off time, manual press the ON/OFF 
button to turn the unit off. 
 
Once the Auto-on or Auto-off time is set, the “T
-On” or “T-Off” and “H” will blink for 2 seconds. 
After 2 seconds the set temperature will be 
displayed. 

Содержание GM-WAC-06ESE-C

Страница 1: ...Models GM WAC 06SE C GM WAC 06ESE C GM WAC 08ESE C Electronic Window Air Conditioner Operating Instructions ...

Страница 2: ......

Страница 3: ...ead this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions 2 This is a safety alert symbol This symb...

Страница 4: ...when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree The power supply cord contains new user serviceable parts Opening the tamper resistant case voids all warranty and per forma...

Страница 5: ...onditioner Remote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip 2 5 Screw for Top Mounting Rail 4 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 4 5 Screw for Window Locking Bracket Accordion Panels 6 Foam Top Window Gasket Owner s Manual 4 ...

Страница 6: ...T TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Model GM WAC 06SE C GM WAC 06ESE C GM WAC 08ESE C Energy Star No Yes Yes Power Supply Ph V Hz 1 115 60 1 115 60 1 115 60 Rated Cooling Capacity BTU h 6 300 6 300 8 000 Cooling Power Input Watts 590 590 740 Rated Current Cooling Amperage 5 3 5 3 7 1 Cooling EER 10 7 10 7 10 8 Noise Level H M L dB A 56 55 54 56 55 54 58 56 54 Ai...

Страница 7: ... 3 The Lower Sash the lower part of the window that moves up and down must allow for 13 25 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord 6 NOTE Save the product packaging and installation instruc tions for future reference Store the air conditioner in the product box when...

Страница 8: ... proper condensation utilization and drainage If you are not using the side panels the rear pitch must still be main tained 1 Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top rail Align along the front edge 2 Attach the top rail onto the top of the outer case using the four 2 5 screws 7 ...

Страница 9: ...attach the window air conditioner to the lower sash See FIG 8 Accordion Panel Installation Now that you have installed the top rail you can now install the accordion panels on each side 1 Place the air conditioner on a hard flat surface 2 Locate the accordion panels in the box 3 Gently pull the free end of the accordion panel See FIG 2 Do this for both panels 4 Slide the free end of the accordion ...

Страница 10: ...roximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drain age See FIG 12 Removing the Air Conditioner from the Window 1 Turn the air conditioner off and disconnect the power cord 2 Remove the sash seal from between windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels in...

Страница 11: ...et light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or remote control The timer can be set in 0 5 hour increment below 10 hours and in 1 hour increment for 10 hours or above The SET light will turn on while setting To see the remaining time press the TI...

Страница 12: ...tioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be in line of site of the A C for iFeel to operate correctly 7 SLEEP MODE Press the SLEEP button to turn SLEEP mode on or off SLEEP mode is set to off automatically When SLEEP mode is selected the time...

Страница 13: ...nd buttons at the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in energy saver mode the Energy Saver light will turn on In Energy Saver mode the unit will turn off once the room is cooled to the user set temperature The fan will also be off at this point The unit w...

Страница 14: ...the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of r...

Страница 15: ...d Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free ...

Страница 16: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Cooling Coils are frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Lower the set thermostat tempera ture Clean the filter See ...

Страница 17: ...r is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and nor mal for a longer period in areas with high humidity 16 ...

Страница 18: ...e performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered Soleus agrees to provide service information sell repair parts and reimburse the dealer serviceman for parts in accordance with Soleus International s Policies and Procedures SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRA...

Страница 19: ......

Страница 20: ...66129908031 ...

Отзывы: