background image

 10 

 

REMOTE CONTROL OPER

ATING INSTRUCTIONS

 

Press the 

ON/OFF (POWER) 

button once to manually 

turn the unit on. Press the Power button once more to 

turn the unit 

  

 

NOTE

: Heat Mode is only 

available on GH-PAC-12E1HP

 

Press the 

MODE

 Button repeatedly to cycle between the 

di erent modes.

 

When the unit is in Air Conditioner or Heater (GH-PAC-

12E1HP) mode you can select your desired temperature. 

Press the 

TEMP SELECT 

buttons (

+

 or 

-

)  to select 

your desired temperature setting. The temperature on the 

LCD display on the remote control will increase or de-

crease accordingly. Hold the +/- buttons for two seconds 

to rapidly increase or decrease the temperature.  Temp. 

range is 61

°

F—86

°

F.

Press the Fan Speed button to change  fan speeds.

 

Fan Speeds:

 

NOTE: When the unit is in Dehumid

 (DRY) mode, 

the fan speed is not adjustable. 

 

Press the Up and Down Swing Button to turn on and   

the vertical swing mode. In vertical swing mode, the lou-

vers will rotate up and down to circulate more air.

 

When the unit is o , press the Up and Down Swing But-

ton and “+” at the same time to enable stationary swing 

mode. Stationary Swing mode allows for more control 

over the way the louvers swing up and down. The Swing 

icon on the Remote LCD will blink twice when this is 

Blinks for 2 Seconds

 

In Stationary Swing mode, press the Up and Down 

Swing Button to change the swing pattern per below:

 

Disable Stationary Swing Mode by pressing the Up and 

Down Swing Button and “+” button at the same time. 

The Swing Icon on the Remote LCD will blink twice 

when this is disabled.

 

REMOTE CONTROL 

MODE 

MODE BUTTON 

ON/OFF 

ON/OFF BUTTON 

FAN 

FAN BUTTON 

- / + 

- / + BUTTONS 

SWING

 BUTTON 

AUTO 

 

COOL 

 

DRY 

 

FAN 

 

HEAT 

Low Speed 

Medium Speed 

High Speed 

SIGNAL TRANSMITTER

 

BLOW

Содержание GH-PAC-12E1

Страница 1: ...Model GH PAC 12E1 Model GH PAC 12E1HP WITH HEAT 12 000 BTU Portable Air Conditioner Operating Instructions ...

Страница 2: ...tioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 12 inches 50 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be co...

Страница 3: ...ONTENTS Portable Air Conditioner Exhaust Hose 1 Front Exhaust Hose Adapter 1 Window Kit Adapter 1 Rear Exhaust Hose Adapter 1 Remote Control AAA Ba tteries 2 batteries Window Kit 3 Sliding Panels 1 sing le hose panel 2 extension panels Owner s Manual Model Ref GH PAC 12E1 GH PAC 12E1HP Power Supply Ph V Hz 1 115 60Hz 1 115 60Hz Dehumidifying Capacity Pints Day 81 81 Rated Cooling Capacity BTU h 12...

Страница 4: ...adapter is available for connecting three pronged plugs into two slot outlets B When doing so the green ground ing tab extending from the adapter must be fastened under the wall plate s mounting screw The adapter should not be used if a three slot out let is available DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG ...

Страница 5: ...PRODUCT DIAGRAM Control Panel 5 Carry Handle Air Outlet Louvers Power Cord Upper Air Intake Lower Air Intake Air Exhaust Vent Filter Location ...

Страница 6: ... door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the REAR and FRONT Exhaust Hose Adapters onto each end of the exhaust hose Once both adapters are attached attach the Window Kit Adapter to the REAR Exhaust Hose Adapter Connect the FRONT Exhaust Hose Adapter to the back of your portable air conditioner Attach the Window Kit Adapter to th...

Страница 7: ...t as flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above Multiple bends will decrease performance and efficiency This installation is OK The is a poor installation 22 26 ...

Страница 8: ...MODE BUTTON TEMP SELECT BUTTONS POWER BUTTON 8 BUCKET FULL LIGHT COOL MODE LIGHT DRY MODE LIGHT FAN MODE LIGHT LED DISPLAY MODE BUTTON TEMP SELECT BUTTONS POWER BUTTON COOL MODE LIGHT HEAT MODE LIGHT FAN MODE LIGHT LED DISPLAY DRY MODE LIGHT ...

Страница 9: ... not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either or key when using the unit in Cooling or Heating GH PAC 12E1HP only mode The digital thermostat will display the set temperature 4 Bucket Full When the unit cannot evaporate the collected moisture fast enough the excess water will collect in a backup water ta...

Страница 10: ...t is in Dehumid DRY mode the fan speed is not adjustable Press the Up and Down Swing Button to turn on and the vertical swing mode In vertical swing mode the lou vers will rotate up and down to circulate more air When the unit is o press the Up and Down Swing But ton and at the same time to enable stationary swing mode Stationary Swing mode allows for more control over the way the louvers swing up...

Страница 11: ...intervals HOUR ON OFF icon will blink when the Auto off Timer is being set To cancel the timer press the ON OFF button Once the timer is set press the TIMER button once more to save the setting Press the ON OFF button to clear a time setting Press the Save button to automatically rotate through the different speeds To disable Save mode and pick your own fan speed press the Save button again This f...

Страница 12: ...atically increase 2 F after 1 hour After 2 hours the set tem perature will decrease another 2 F for a total decreaseof 4 F REMOTE CONTROL SLEEP SLEEP BUTTON LIGHT BUTTON Blow Blow LOCK LOCK FUNCTION Press and buttons toge ther at the same time to lock the remote keyboard Do this again to unlock AUTO AUTO MODE Press the MODE button to select Auto Mode Once Auto Mode is selected the unit will automa...

Страница 13: ...dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess wat...

Страница 14: ...vice technician TROUBLESHOOTING The Air Conditioner does not cool as it should The Dehumidifier function is not providing cool air as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Evaporator is frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditio...

Страница 15: ...t If E5 is still dis played contact customer service TROUBLESHOOTING CONT The LCD Display is showing H8 The backup water tank is full Drain the water tank If the H8 I still displayed after the water tank has been emptied con tact customer service The LCD Display is showing F1 F2 or F4 Internal malfunction Contact Customer Service 15 ...

Страница 16: ...rance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR ...

Отзывы: