Problem
Possible Causes
Solutions
Water on the floor
Hose connection may be loose.
Check the hose connection. See the
CONTINUOUS MODE
-
GARDEN HOSE INSTALLATION AND SET UP
Section on
Page 10.
Hose is attached but not draining
into a drain.
Disconnect the hose if using the bucket or place the hose near
a drain.
Unit will not turn on
The fuse is blown / circuit break-
er is tripped.
Check the house fuse / circuit breaker box and replace fuse or
reset breaker.
Unit is on but fan is not
running
Dehumidifier has reached its
present level or the bucket is full.
The dehumidifier automatically turns off when either condi-
tion occurs. Change to a lower setting or empty the water
bucket and replace properly.
Bucket is not in the proper
position.
The bucket must be in place and securely seated for the dehu-
midifier to operate.
Power failure.
There is a protective time delay (up to 3 min.) to prevent trip-
ping of the compressor overload. For this reason, the unit may
not start normal dehumidification for 3 min. after it is pow-
ered back on.
Pump Mode is on, but water is
draining in bucket
Incorrect drain hose is installed.
Make sure that the included plastic drain tube and nozzle
adapter are tightly installed.
Continuous Mode is on, but
water is draining in bucket
Incorrect drain hose is installed.
Garden hose must be used while operating Continuous Mode.
Dehumidifier on uneven surface.
Make sure that the unit is placed on a flat, level surface.
TROUBLESHOOTING