![Solectria Solar Rapid Shutdown Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/solectria-solar/rapid-shutdown/rapid-shutdown_installation-and-operation-manual_1314687003.webp)
FOR
PVI
3800-7600TL
3
Rapid Shutdown Combiner Installation and Operation Guide (Rev B)
DOCR-070566-B
CAUTION
- Risk of electric shock from energy stored in capacitor. Do not remove
cover until 5 minutes after disconnecting all sources of supply.
WARNING
- For continuous protection against risk of fire, replace only with same
type and ratings of fuse.
WARNING
- The RSD Combiner surfaces may become hot. To reduce the risk of
burns, do not touch them.
PRUDENCE
- Quand les panneaux photovoltaque sont exposes a la lumiere, ils
fournissent une tension en courant continu a l equipement.
PRUDENCE
- Le botier ne doit en aucun cas être ouvert. Aucun composant interne
n'est à entretenir. Reportezvous à un technicien qualifé pour tout entretien.
PRUDENCE
- Risque de choc électrique à partir d'énergie stockée dans les
condensateurs. Retirer le couvercle
AVERTISSEMENT
- Du botier au moins 5 minutes après avoir débranché toutes les
sources. d'approvisionnement.
AVERTISSEMENT
- Le chassis de l’onduleur et les surfaces des dissipateurs de
chaleur peuvent devenir chaud.
2.
Rapid Shutdown Combiner
The Solectria RSD Combiner provides an automatic disconnect of 600 VDC residential
or small commercial PV array systems, fully compliant with the Rapid Shutdown
requirements of NEC 2014 article 690.12 when installed appropriately. It is compatible
with Solectria’s single-phase residential inverters: PVI 3800TL, PVI 5200TL, PVI 6600TL,
and PVI 7600TL.
Solectria’s RSD Combiner must be installed within 10 feet of the PV array when
mounted outside or within 5 feet after entering a building in order to comply with NEC
690.12. The RSD Combiner is capable of being mounted to the top of a standard
mounting rail beneath a PV module or indoors. Please refer to section 4 for details.
The RSD Combiner has two discrete 2 position fused PV string inputs. Each pair of
modules combines into a single output where the DC output conductors are routed to
the MPPT zone bypass terminals in the PVI single phase inverters. For use with the PVI
3800TL, only one input (2 positives) of the RSD Combiner can be used. For the PVI
5200TL, PVI 6600TL, and PVI 7600TL inverters, all inputs of the RSD combiner should
be used. It is acceptable to use only 2 or 3 of the 4 positions based on the PV array
design.