Installation
3-7
SkyWay-EB Series
Tightly screw in the compression nut, as shown in Fig. 3-10 to complete the conduit connection. The o-
ring will provide water seal at this cable entry point.
Figure 3-10
Connect the cables to appropriate ports. Do not take out the screws – spade lug connectors can be slid
in with the screws loosened. Please refer to the following tables for the correct cable connection.
3-5-2. Connecting the AC Power Source
There are 3 terminal blocks to connect the power source inside the SkyWay-EB units. The connection is
fastened with M3 bolts.
As for the electric wire coming from the outside, use the wire with the diameter of 0.75mm or larger to
stably supply the electricity.
It is recommended to use the ring type tinned copper terminal end or PVC insulated type tinned copper
terminal end to connect the terminal block and the wire. The internal diameter of the solderless terminal
should be 3.2mm.
Table 3-1 Terminal Blocks Connecting the Power Source
Terminal
NC Terminal
(+)V Terminal
(-)V Terminal
When using a - 48V source
NO connection
Ground wire
-48 V wire
When using a +48V source
NO connection
+48V
Ground wire
•
•