background image

 

 

© CASWA Pty Ltd – 2012 

 

10 | Page 

 

4

 

COMMISSIONING DETAILS 

AirWay is designed to be commissioned using a laptop computer.  You will need a CASWA LINK-2 
Bluetooth Modem and the Field Service Utility (FSU) software application loaded on a laptop. 

 

4.1

 

Installing and Launching the FSU Application 

4.1.1

 

FSU Program Installation 

Ensure that your computer is switched on, connected to the internet and that the minimum required 
software versions are installed (see 0 for minimum system requirements).  Ensure that the LINK-2 
modem is installed and that the drivers have loaded. 

More information on installing the LINK-2 modem can be found in the document Link-2 installation, 
which can be downloaded from 

http://www.Liftlog™.com.au/literature.asp

 

 

4.1.2

 

Installing the FSU application  

The latest LINK-2 FSU software (Link-2_FSU) can be downloaded from 

http://Liftlog™.com.au/updates.asp

 

You should check this location periodically for updates and information.   

 

4.1.3

 

Launching the application 

Double click on the FSU program icon: 

 

 

Содержание AirWay AWT100

Страница 1: ...AirWay Wireless Signal Transceiver Model AWT100 Version 1 0 Installation and User Manual V1 2 28 08 2012 CASWA Pty Ltd 2012...

Страница 2: ...logXL 8 3 2 3 Implementing a Link Status Output 9 4 COMMISSIONING DETAILS 10 4 1 Installing and Launching the FSU Application 10 4 1 1 FSU Program Installation 10 4 1 2 Installing the FSU application...

Страница 3: ...eives up to 4 input output control signals It can be used to provide remote I O for products such as CASWA s Liftlog or Liftlog XL data logger where the desired signals cannot be cabled into the logge...

Страница 4: ...y Ltd 2012 4 Page 2 SPECIFICATIONS 2 1 Physical Specifications Overall length mm 161 Overall width mm 91 Overall height mm 30 Weight kg 0 2 Mounting 2 x 8 5mm screws OR 4 x 5mm screws Figure 1 Case Di...

Страница 5: ...n the device and a host is usually via a Bluetooth radio link The Bluetooth device name will be set to the Crane ID the PIN is 0000 For more details on the communication protocol used to communicate w...

Страница 6: ...curely Remove the cover by undoing the 4 screws on the rear of the device to access the circuit board and screwed terminals inside The board is shown in Figure 2 AirWay has four single wire digital in...

Страница 7: ...ns 3 4 5 6 7 8 and 9 10 are Normally Open and rated for 250V AC 32VDC 4A They can be reconfigured to Normally Closed using the FSU software 1 0V 4 5 13 Input 2 2 32 240VAC 8 7 3 6 9 10 11 Input 4 12 I...

Страница 8: ...Figure 4 provides the wiring details for using an AirWay to transmit the longitudinal travel motions from a LiftlogXL Figure 4 Connecting an AirWay to Provide Remote Inputs for Long Travel on a Liftlo...

Страница 9: ...ly voltage the AirWay will send the assigned signal continuously once a connection is made The receiving device can then determine when a link is active Figure 5 Implementing a Link Status Output 1 0V...

Страница 10: ...mum required software versions are installed see 0 for minimum system requirements Ensure that the LINK 2 modem is installed and that the drivers have loaded More information on installing the LINK 2...

Страница 11: ...and press Connect 4 3 Checking for Firmware After you have selected your desired AirWay a connection will be made and the software will check if the device has the current firmware If a new firmware v...

Страница 12: ...rWay being configured To enter change the CraneID type the desired name into the ID field 4 5 Binding the AirWay to a Device Unless your AirWay device has been preconfigured You will need to select th...

Страница 13: ...ons one that might be used when the AirWay being configured is bound to a second AirWay unit and a simple 1 to 1 mapping of inputs and outputs is required The second example would be typical of an Air...

Страница 14: ...ERATING BEHAVIOUR The AirWay is fitted with a multi colour LED on the front panel that indicates connectivity This has two modes Green Connected Red Not Connected A connection usually takes about 5 se...

Страница 15: ...CASWA Pty Ltd 2012 15 Page 6 ROUTINE MAINTENANCE There is not routine maintenance for this device...

Страница 16: ...except for the u and E commands the requested value in ASCI text followed by a CR Where the command is a set command an argument may be included between the command and the CR Where numbers are sent o...

Страница 17: ...ENDIX B FSU SYSTEM REQUIREMENTS The minimum requirements for operating CASWA s Field Service Utility FSU and Link 2 Bluetooth modem are Laptop computer running Windows XP SP3 or later One Spare USB po...