Motor assembly specification

 

 

 

Fan motor assembly:

 

100 mm in-line

 

Max operating temperature:

 

40°C

 

Motor: 

Powerful, yet quiet unobtrusive single phase 
induction motor with backward curved 
centrifugal impellers for a large airflow 
providing a long maintenance-free life

 

Moisture:

 

Suitable for a wide range of applications 
including bathrooms, toilets, shower 
rooms and utility rooms. 
Not suitable for kitchens.

 

Supply: 

220-240V 

– AC 50Hz

 

Fan Speed:

 

1400 rpm

 

Airflow: 

Extract rates of 110m³/hr / 31 litres per second

 

Maximum pressure:

 

120 Pa 

 

Compliance: 

Designed to comply with the 2006 Building 
Regulations on Ventilation (F1)

 

CE label

 

Flexible duct:

 

Local Building Codes may require air 
duct (class 0) for certain fire-rated 
installations

 

 

 

Step 1 

– marking location for the fan motor assembly 

Refer to the Solatube Brighten Up Series installation guide to 
mark the ceiling and roof location of the Solatube 160 DS 
Daylighting System. 
 
In the roof void, locate a mounting location that allows the fan to 
be installed 

horizontally

. Check that wiring can be run to the 

planned location and that the ducting supplied can reach this 
location from the roof exit and ceiling location respectively, 
allowing for a u-bend in the duct to act as a condensation trap. 
Refer to the installation instructions supplied with the fan motor 
assembly 

(diagram A). 

D

iagra

m

 A

 

 

Step 2 

– mark the location for the ventilation housing 

Using the grille assembly as a guide, make a template from card 
(you could use the Solatube packaging), ensuring you cut the 
template 20mm smaller than the outer edge of the grille assembly.    
 
Place the template on the ceiling surface within the roof void, 
ensuring it aligns with your ceiling marker and draw a line around 
the template 

(diagram B)

.

 

 

D

iagra

m

 B

 

 

 

Step 3 

– install the ventilation housing 

Cut along the line and remove the ceiling material. Remove the 
screw backing tabs from the ventilation housing. Secure the 
ventilation housing with six No.6 (40mm) drywall (ceiling) screws 
and the six screw backing tabs 

(diagram C). 

 

NOTE: For an air infiltration seal, apply a 5mm bead of sealant to 
the back of the ventilation housing prior to installation. 

 

D

iagra

m

 C

 

 

Step 4 

– install the fan motor assembly & switch 

 

Please refer to the separate installation guide enclosed for mounting and wiring the motor assembly and switch. Ensure 
the fan motor is mounted horizontally. 

Step 5 

– connect the ducting 

Run the air duct from the 100mm diameter upstand spigot to the 
inlet of the fan motor assembly. On the exhaust side of the fan 
motor assembly, run the air duct to the fascia/soffit exit vent or 
optional roof vent (see separate installation guide provided with 
optional roof vent).  
 
For best venting performance, make the air duct run as short as 
possible with minimum bends, cutting the duct as necessary. 
 
Ensuring an overlap of at least 25mm, secure the duct at each 
connection using the zip ties supplied and then cover with duct 
tape to create a seal 

(diagram D)

Diagra

m

 D

 

 

 
 
 
 

Joists 

Select a mounting location that allows 
the fan motor to be installed horizontally  