Troubleshooting 

All observations for potential faults need to be conducted in clear daylight conditions. 

 
Observation 

Fault 

Dim/flickering LCD display 
& lights

 

Should this occur in bright sunshine please 
contact your installer. No Fault if seen in low 
light conditions. Re-check in brighter 
conditions. 
Please see note in Frequently Asked Questions  

LCD continually resets with 
35 second timer 

During Periods of low light the LCD display may 
be observed resetting in a loop until there is 
sufficient power from the array to maintain 
stability. 

Flashing temperature 
lights (Orange LEDs) 

Fault with storage water temperature sensor or 
internal temperature of the enclosure is too 
high e.g. Controller mounted in full direct 
sunshine or over voltage from array. 

No heating light  
(Green heating LED) 

Element not powered. The controller will only 
energise the element when there is enough 
solar energy available and the storage water 
temperature is below the set point. If clear 
conditions, the water is cold and no green light 
appears, contact your installer. Also see FAQ. 

Heating light on but no hot 
water. (Green Heating LED) 

Not enough heating time has passed. Allow 
more time for heating.  If light is on but LCD 
display shows no Power (Watt) figure contact 
your installer. Possible Element Fault. 

Flick of green light 
(Green Heating LED) 

Approximately every 20 seconds. This is the 
unit  testing the power available. A high voltage 
may display but no current may be available. 
Not enough sunlight to engage element. 

No power light. 
(Red LED) 

Not enough power being produced by the main 
array. If in sunny clear conditions contact your 
installer. 

No temperature lights 
(Orange LEDs) 

Average water storage temperature is below 32 
degrees Celsius 

 

 

Содержание PV360BMS Shared

Страница 1: ...uipment PV DC Electric Hot Water Product Manual 1 52 Barnett Ave Glynde SA 5070 Phone 08 8337 8881 www solatherm com au Model PV360SWTSwitched PV360BMS Shared Heating with Secondary Output Power Contr...

Страница 2: ...t water circuit including work that partially or completely drains the storage vessel ensure all electrical supplies the Photovoltaic array and AC connection have been disconnected as per the System S...

Страница 3: ...ous voltages Removal of the covers on the storage water vessel will expose live electrical wiring Covers must only be removed by an authorised service person and only once dual supply power has been i...

Страница 4: ...the water heater exploding Water may drip from the discharge pipe but continuous leakage from the valve may indicate a problem with the water heater please have your water heater serviced by a qualif...

Страница 5: ...ting Clearances and Mount Point Locations 14 Connection Controller to Storage Water Vessel 15 Wiring Diagram PVOTC Element 16 Connection Main Array Input 17 Connection Secondary Output 18 Connection B...

Страница 6: ...ormation when there is sufficient energy from the sun It is normal for the LCD display and lights to flicker or not fully display in low light conditions During periods of low solar input where there...

Страница 7: ...total kW h consumption 2 Power red LED illuminated red when the main array is connected and supplying power to the unit In low light conditions this light may be the only LED lit or flashing 3 Heating...

Страница 8: ...7 P a g e Basic System Configuration Figure 2...

Страница 9: ...er the start up sequence is complete the green heating LED will light up if sufficient power is available to commence heating Note The controller has several built in time delays of up to 1 5 minutes...

Страница 10: ...un is out A 1 The water in the storage tank is up to temperature Dependant on the factory set temperature 600 C or 700 C 2 During periods of low light intensity such as early morning late evening or i...

Страница 11: ...ster is connected and the AC boost timer settings are correct for the household demand or season Q I can see the second output is active but I have no hot water 1 A There is a fault with one of the te...

Страница 12: ...No heating light Green heating LED Element not powered The controller will only energise the element when there is enough solar energy available and the storage water temperature is below the set poi...

Страница 13: ...12 P a g e Installation Instructions Wiring Diagram Controller WARNING INCORRECT POLARITY WILL DAMAGE THE CONTROLLER NO WARRANTY FOR POLARITY DAMAGE Figure 3...

Страница 14: ...roller out of the direct sunlight as it will make visual reading of the LCD display difficult 3 The control box shall be 3 x point screw mounted via the attached slotted metal brackets at the top and...

Страница 15: ...14 P a g e Mounting Clearances and Mount Point Locations Figure 5...

Страница 16: ...d to the inside of the element enclosure cover and per the labelled colour coded connection points within 4 Connect the 2 x colour coded NTC sensor wires into colour coded mounting block See Figure 7...

Страница 17: ...m PVOTC Element PVOTC is only activated by overheating of the storage vessel which indicates a potential system fault The PVOTC is a onetime operation and is NON RESETABLE If activated the PVOTC must...

Страница 18: ...age from array Confirm correct for controller model and cylinder element 3 Connect MC4 Connectors to controller input only when ready to commission See Commissioning Start up pg 19 Ensure polarity at...

Страница 19: ...the 400mm long output diversion cable D into Isolator and direct to auxiliary device as required See Wiring Diagram Controller Figure 3 and Figure 9 Element storage vessel E Main Array via Isolator A...

Страница 20: ...wiring instructions affixed inside the cover The standard booster element is 2 4Kw 10Amp but this may vary depending on application ensure to identify and wire to suit load The hot water vessel must b...

Страница 21: ...of 3 4 5 or 6 panels per string depending on the model and DC element The supply from the main array must be tested and identified to be strung correctly with the correct number of panels to suit the...

Страница 22: ...rt up sequence is complete the green heating LED will light up if sufficient power is available to commence heating Note The controller has several built in time delays of up to 1 5 minutes to allow f...

Страница 23: ...ined as a single family domestic home with a setting of less than 750 C 2 Commercial encompasses all other applications 3 Components include dedicated DC heating element PV Over Temperature Cut Out te...

Страница 24: ...e due to misuse incorrect installation unauthorised attempts to repair the system 2 Where there is nothing wrong with the control unit and the problems relates to incorrect installation or abnormal co...

Страница 25: ...ter Controller Controller Model Serial Number All Output Connections terminated Y N Cylinder Full of Water Y N Storage Cylinder Earthed Y N VOC at Isolator V Is DC Voltage with in operating limits of...

Страница 26: ...rs recorded Y N Are all labels installed as per AS4777 1 Y N Have all roof tiles iron sheets been re installed Y N Have all the required customer signature fields been signed Y N Is the array installe...

Страница 27: ...gram This diagram must be fully completed and retained with all COC s for service personnel Capacity L Model Date Created Array Size kW Panels Strings DC Cable Size mm2 DC Isolator Is Array Earthed Y...

Страница 28: ...ting Altitude 4000m Safety Regulation IEC 62109 Cooling Natural Convection Pollution Degree PD2 Weight 2 3 kg Overvoltage Category OVC II Environment Outdoor Location Classification Suitable for Wet a...