![Solartron Digital Input/Output Module Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/solartron/digital-input-output-module/digital-input-output-module_manual_1314048012.webp)
I/O Port: Output Specification - Driver
Configuration Using Orbit Supply
+5 V Orbit Supply (pin 13 DIOM connector):
Maximum 50mA total current is available from
the Orbit supply via the DIOM. This can be used
for external loads such as active switches,
indicators and sensing devices.
• Open drain
• Low-level output voltage
≤
+0.2 V
Absolute Maximum -Total
I
Orbit(MAX)
≤
50mA (source total)
2.0:
Detail Specification
2.0: Detail Specification
10
Manual No. 502237 Issue 2