3.3: Pneumatic Actuator Installation
1. Unscrew and remove the spring holder (5).
2. Remove the spring (6) if it is installed.
3. Install a spring and spring holder opposite to
where the pneumatic actuator is to be installed
4. Insert the pneumatic actuator (4) and screw until
tight. Do not overtighten.
4
6
5
3.0: Mechanical Installation
3.0: Mechanical Installation (continued)
To maximise the working life of the Block Gauge, the
air supply should be both clean and dry for continual
reliable operation. The air should have a maximum
relative humidity of 60% RH and be filtered to better
than 5 µm particle size.
When fitting a pneumatic actuator, ensure that
threads in the Block Gauge and the actuator are
clean. In order to avoid damage to the actuator or
the Block Gauge, it is important not to exceed the
specification for air pressure.
CAUTION
The pneumatic Block Gauge works at
a higher air pressure than pneumatic
gauging probes. In order to avoid
damage to gauging probes when used
in conjunction with Block Gauges, it
is important that separate air pressure
regulators are used for each product
type.