SR971,SR972 Solar station operation manual
-------------------------------------------------------------------------------------------------------------------------------------
31
parameters are saved automatically.
7.6 Main menu TEMP Temperature
For every system, the factory set parameters are in the best condition that is fully integrated
into the entire solar system. But these parameters can also be set individually to cater the
special requirements, please carefully observe the operation data of system components
after setting.
Note:
Parameters that can be set depend on the selected system, not all the parameters can be
adjusted in a solar system.
Following submenu can be access though TEMP main menu.
EMOF
Collector safety switch-off temperature ---------------------------------------------7.6.1
EMON
Collector safety recovery temperature ------------------------------------------------7.6.1
CMX
Maximum limited collector temperature (collector cooling function) ---------- 7.6.2
CMN
Low temperature protection of collector ------------------------------------------- 7.6.3
CFR
Frost protection of collector ------------------------------------------------------------7.6.4
REC
Tank recooling temperature ------------------------------------------------------------7.6.5
SMX1
Maximum temperature of tank ------------------------------------------------------- 7.6.6
C-F
Celsius and Fahrenheit temperature transferring-----------------------------------7.6.7
Function
Adjustable range
Factory
set
Function
exit
temperatu
re
EMOF Collector safety switch-off
temperature
(
ON+3
℃)~
200
℃
130
℃
EMON Collector safety recovery
temperature
(
OFF-3
℃)~
197
℃
120
℃
CMX Maximum limited collector
temperature (collector cooling function)
90
℃~
180
℃
110
℃
107
℃
CMN Low temperature protection of
collector
0
℃~
90
℃
OFF