background image

SOLARIS® SMART54™

6

7

SOLARIS® SMART54™

INSTALLATION

The fixture is designed for indoor use only and must be used in a dry location with adequate 

ventilation. Ensure that none of the fixture’s ventilation slots are blocked and ensure that the 

fixture is fastened to a secure structure or surface. Do not use the fixture to illuminate sur

-

faces less than 8 m (appx 26ft.) from the fixture.

FASTENING THE FIXTURE TO A FLAT SURFACE

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure 

that the surface and all fasteners used can support at least 10 times the weight of all fixtures 

and equipment they will support. Fasten the fixture Securely. Do not place it on a surface or 

leave it where it can be moved or fall over. If you install the fixture in a location where it may 

cause injury or damage if it falls, secure it as directed below with a securely anchored safety 

cable that will hold the fixture if the primary fastening method fails.

MOUNTING THE FIXTURE ON A TRUSS

The fixture can be clamped to a truss or similar rigging structure in any orientation. When 

installing the fixture hanging vertically down, you can use an open-type clamp such as a 

G-clamp. When installing in any other orientation, you must use a half-coupler clamp

that completely encircles the truss or pipe circumference. To clamp the fixture to a truss:

1. Check that the rigging structure can support at least 10 times the weight of all fixtures and 

equipment  to be installed on it.

2. Block access under the work area.

3. Working from a stable platform, hang the fixture on the

 truss and  fasten the rigging clamps onto the truss.

4. Secure the fixture with a safety cable as directed below.

5. Check that the head will not collide with other fixtures or objects.

SECURING WITH A SAFETY CABLE

Secure the fixture with a safety cable (or other secondary attachment) that is approved for 

the weight of the fixture so that the safety cable will hold the fixture if a primary attachment 

fails. Loop the safety cable through and around a secure metal anchoring point.

WARNING! READ SAFETY INFORMATION ON    

PAGE 3 BEFORE INSTALLING THE FIXTURE.

Socket outlets or external power switches used to supply the fixture with power must be 

located near the fixture and easily accessible so that the fixtures can easily be disconnect

-

ed from power.

Do not insert or remove power cable to apply or cut power, as this may cause arcing at the 

terminals that will damage the connectors.

Do not use an external dimming system to supply power to the fixture, as this may cause 

damage to the fixture that is not covered by the product warranty.

The fixture can be hard-wired to a building electrical installation if you want to install it 

permanently, or a power plug (not supplied) that is suitable for the local power out- lets 

can be installed on the power cable.

If you replace power plug on the power cable, install a grounding type (earthed) plug with 

integral cable grip that is rated minimum 250 V, 5 A.

The fixture has an auto-ranging power supply that accepts AC mains power at 100-240 V 

at 50/60 Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.

For protection from electric shock, the fixture must be grounded (earthed). The 

power distribution circuit must be equipped with a fuse or circuit breaker and 

ground-fault (earth-fault) protection.

AC POWER

WARNING! READ SAFETY INFORMATION ON    

PAGE 3 BEFORE INSTALLING THE FIXTURE.

Содержание SMART 54

Страница 1: ...USER MANUAL...

Страница 2: ...essional certified technicians Do not open the housing or attempt any repairs All applicable local codes and regulations apply to proper installation of this product PERSONAL SAFETY Avoid direct eye e...

Страница 3: ...for Venue Installations Theatrical Cinema TV and Stage Use The fixtures is deemed for its silent operation achieved by temperature detectors and silent fans The Unit is made of a sturdy aluminum cast...

Страница 4: ...lamps onto the truss 4 Secure the fixture with a safety cable as directed below 5 Check that the head will not collide with other fixtures or objects SECURING WITH A SAFETY CABLE Secure the fixture wi...

Страница 5: ...ture has 3 pin XLR connectors for DMX data input and output The number of daisy chained fixtures is limited by the number of DMX channels required by the fixtures in relation to the maximum 512 channe...

Страница 6: ...plays So02 the fixture will strobe using sound signal which is detected using the built in microphone at the back of the fixture You can also manually control strobe flashing by changing the values wh...

Страница 7: ...16 Auto Color Changing mode Up Down Buttons change speed 01 16 r255 Red Up Down Buttons change Red intensity 000 255 G255 Green Up Down Buttons change Green intensity 000 255 B255 Blue Up Down Buttons...

Страница 8: ...ot use any product that con tains solvents or abrasives as these can cause surface damage CLEANING THE FIXTURE 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum...

Страница 9: ...IONAL NAME AND ALL OTHER TRADEMARKS IN THIS DOCUMENT PERTAINING TO SERVICES OR PRODUCTS BY GLOW PROFESSIONAL OR ITS AFFILIATES AND SUBSIDIARIES ARE TRADEMARKS OWNED OR LICENSED BY GLOW PROFESSIONAL GL...