17 Troubleshooting
17 Troubleshooting
Faults that occur are displayed in an information win-
dow in the control and each message is save in the
message log
.
Fig. 2-58: Note window Fault
Handling of messages
–
Button
1
: Close window, change to main screen.
The fault message remains active, i.e. the burner
may not start depending on the type of message.
–
Button
2
: Switch to the
message log
–
Button
3
: Acknowledge the message.
An acknowledgement is only possible if the cause
of the fault has been rectified; the burner may then
restart after a heating request is received.
An alarm message is visible at the top edge of the
main screen until it is acknowledged
1
. Press to ack-
nowledge the message (message window opens)
Fig. 2-59
Alarm symbol
This symbol indicates an alarm message: The
boiler is no longer ready for operation if such a mes-
sage occurs.
Note symbol:
This symbol indicates an alarm message: The
boiler is still ready for operation.
Possible messages:
In accordance with the prevailing message, it is deter-
mined who is supposed to take the required action
(system operator
SO
or qualified personnel
QP
).
No. Message
AB FP
1 Error in internal memory
x
2 Feeder sensor short circuit
x
3 Ignition not possible Check the container
fill level sensor
x
4 Extraction room may be empty
x
5 Flue gas temperature too low
x
Flue gas sensor interruption
x
7 Flue gas sensor shows wrong measured
value
x
8 Feeder sensor interruption
x
9 Flue gas sensor short circuit
x
10 Factory settings loaded
x
11 ID fan error
x
12 ID fan test running
x
13 The functionality of the induced draught
fan is no longer intact
x
14 Maximum suction time reached
x
15 Feeder sensor shows the wrong measured
value
x
16 Lambda sensor faulty
x
17 Boiler sensor defective
x
18 Boiler temperature is too high
x
19 Extraction auger is blocked
x
x
20 First ignition attempt failed
x
21 Triac output feeder defective
x
22 Triac output room extraction defective
x
23 DFSH module communication error
x
24 Overtemperature reset or safety chain has
been triggered
x
25 Power failure detected
x
26 Mains fuse defective
x
27 Triac fuse defective
x
30 Feeder is blocked
x
31 Heat exchangers are blocked
x
32 Heat exchangers are blocked
x
33 Line interruption to feeder motor
x
35 CAN bus interruption
x
36 Fuse at fresh water module defective
x
37 Fuse on module defective
x
38 Commissioning settings loaded
x
39 Solar setting
Max. tank temperature bot-
tom
can trip safety temperature limiter
x
x
40 Ignition not possible
x
x
41 Fuse F1 or F8 defective
x
Operation manual
pellettop
37