4 Product information
Caution with (older) diffusion-open plastic pipes,
e.g. existing underfloor heating
–
In the case of older underfloor heating, the dif-
fusion-open plastic pipes can result in increased
oxygen input in the heating system. This has a cor-
rosion-inducing effect on the heating system com-
ponents (see: Avoiding water-side corrosion
).
–
In this case, the system must be separated
(through installation of a heat exchanger).
–
Newer plastic pipes (since around the mid 1980s)
are diffusion resistant in line with DIN 4726.
Buffer tank: Use, dimensioning
Advantages of using a buffer tank:
–
The boiler can always be operated in the optimum
load range. This results in a longer boiler service
life and reduces emissions.
–
Avoids unnecessary boiler start phases, the hig-
her fuel consumption during the start phases is
significantly reduced.
–
Continuously heated water is available in the buf-
fer tank for the heating circuit. The heating circuits
can therefore always be quickly supplied with
heat at all times.
If the heating system is operated without a buffer
tank, a hydraulic switch
must be installed.
Dimensioning the buffer tank:
For pellet boilers, a buffer tank volume of at 30 litres
per kW heating output is recommended.
Hydraulic switch
–
A hydraulic switch separates the flows in the boi-
ler and heating circuits.
–
If the heating system is operated without a buffer
tank, a hydraulic switch must be installed bet-
ween flow and return.
Installing the dirt and sludge separator
–
The separator removes circulating, magnetic and
non-magnetic free dirt and sludge particles (as of
5 μm) in fully-automatic continuous operation
from the heating system.
–
Ensures the long-term, correct functioning of heat
generators, thermostatic valves, heat exchangers
and lowers the risk of defects and malfunctions
over the long-term.
–
Helps ensure quality heating water, even in the
case of existing systems, for example.
4 Product information
4.1 Scope of delivery
Qty.
Designation
1
Boiler, preassembled
1
Return flow booster, integrated
2
Combustion grate
1
Bag (transparent) with outdoor temperature sen-
sor
1
Flue pipe extension
from
∅
80 to
∅
100 mm for pellet
elegance
10/15
from
∅
100 to
∅
130 mm for pellet
elegance
20/24
Further information
1
Operation manual
1
Installation manual
Not included in the standard scope of delivery:
–
Pellet hose
–
Flue pipe to chimney
–
Chimney connection material
–
Integratable heating circuits HC1, HC2.
4.2 Accessories
Lifting aid
–
Optional accessories for carrying/moving the boi-
ler.
–
Art. 6144
Abb. 2-2: Lifting aid mounted
10
Installation manual
pelletelegance