5 Use and operation
5.4.6 Qualified personnel menu
Abb. 2-18
1 Service menu
2 IP VNC (for remote access)
3 Sending emails
4 mySOLARFOCUS-App
5 Language selection
6 Date and time
5.4.6.1 Service menu
In the
Service menu
there are technical (factory pre-
defined) settings for an optimum combustion process
in the boiler. These can only be accessed by qualified
personnel (code input required).
5.4.6.2 IP VNC (for remote access)
The
eco
manager-
touch
control allows access to the con-
trol screens from a PC or mobile device (e.g. smart-
phone). To do so, the
VNC
(Virtual Network
Computing) software is used. The control has an inte-
grated VNC server, while the
VNC Viewer
, which is
available free of charge on the Internet, is required for
remote access.
A cable connection is required on site for connecting
the control to the router. Use the Ethernet socket
(type RJ45) on the rear of the control panel (Touch
display).
i
Installation and configuration of this function
must be performed by the customer (i.e. not
included in the commissioning, service and
support activities).
The following points are helpful for setting up a PC/-
router to control the VNC server, which requires know-
ledge of networking technology.
IP configuration
►
To access the
IP-VNC
icon, select the following
in the control
–
Selection menu
screen
–
Customer menu
screen
–
Qualified personnel button
►
Enter the data for your router. Recommended
process:
–
Select
DHCP ON
.
Ä
The IP address is determined.
–
Select the
DHCP OFF + Adopt
button.
Abb. 2-19
–
The IP address must be unique in each Ethernet
network and is dependent on the other network
components (PC, modem/router, etc.).
–
Recommendation: Set a fixed IP address
(=
DHCP OFF
), i.e. the control has a constant IP
address.
Version 1: Install VNC viewer for access from a
local PC (PC in the home network)
►
Download the free VNC Viewer from the Internet,
install it on the PC and start the application.
►
Enter the previously defined IP address of the
control.
–
As soon as the VNC Viewer is able to access
the control, a password must be entered.
–
The password predefined by the manufacturer
is
solarfocus
–
After login, the screen view of the control can
be seen.
Operation manual
pelletelegance
17