Inverter Configuration – Setup Mode
You can configure the inverter using one of the following:
l
. When using this option, the inverter cover is removed.
l
. This option of configuration includes a less detailed configuration
menu.
Configuring the Inverter Using the LCD User Buttons
After inverter installation, an installer may perform basic system configuration. Configuration is done
when the inverter is in Setup mode.
To enter Setup mode:
1. Turn the inverter ON/OFF switch to OFF (AC remains ON).
WARNING!
If the inverter was operating properly (power was produced by the power optimizers), the
following message is displayed.
D C V O L T A G E N O T S A F E
D O N O T D I S C O N N E C T
V D C :
7 2 . 0
This message is displayed until the DC voltage is safe (50V). Do not open the cover until the
voltage is safe or until at least five minutes have passed.
2. Press the Enter button for at least 5 seconds. The following message is displayed:
P l e a s e e n t e r
P a s s w o r d
* * * * * * * *
3. Use the three rightmost internal LCD user buttons to type in the following password:
12312312
. The
following menu is displayed:
C o u n t r y < I t a l y >
L a n g u a g e < E n g >
C o m m u n i c a t i o n
P o w e r C o n t r o l
B a c k u p C o n f < D i s >
D i s p l a y
M a i n t e n a n c e
I n f o r m a t i o n
The inverter is now in Setup mode and all its LEDs are lit. The inverter automatically exits Setup mode if no
buttons are pressed for more than 2 minutes.
The following shows a hierarchical tree of the menu options, which are described in
on page 48. Actual menus may vary from shown depending on the firmware version of the
inverter and on the country.
Chapter 7: User Interface
SolarEdge
-