SolarEdge StorEdge BI-NUSGN-01 Скачать руководство пользователя страница 1

 Installation Guide

Backup Interface for Single 
Phase Energy Hub Inverter with 
Prism Technology

for the main lug only

North America

Version 1.0

Содержание StorEdge BI-NUSGN-01

Страница 1: ...Installation Guide Backup Interface for Single Phase Energy Hub Inverter with Prism Technology for the main lug only North America Version 1 0...

Страница 2: ...wever discrepancies cannot be excluded No guarantee is made for the completeness of these documents The images contained in this document are for illustrative purposes only and may vary depending on p...

Страница 3: ...is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to...

Страница 4: ...p Interface Interfaces 13 Connecting the Backup Interface to the Grid and AC Loads Panel 13 Connecting the Backup Interface to the Inverter 15 Connecting the Backup Interface to an External Rapid Shut...

Страница 5: ...Revision History Version 1 0 April 2020 First version of this guide Backup Interface Installation Guide MAN 01 00728 1 0 4 Revision History...

Страница 6: ...faite ou suivi correctement pourrait causer des blessures ou un danger de mort Ne pas d passer une telle note avant que les conditions requises soient totallement comprises et accomplies CAUTION Denot...

Страница 7: ...le installation and connectivity to other system components and includes a DC Safety Switch Backup Interface optional controls disconnection of house loads from the grid and integrates the following c...

Страница 8: ...ion Allen screwdriver for 5mm screw type for the inverter enclosure screws Standard flat head screwdrivers set Non contact voltage detector Cordless drill with a torque clutch or screwdriver and bits...

Страница 9: ...For installing the communication options you may also need the following For Ethernet CAT5 6 twisted pair Ethernet cable with RJ45 connector If using a CAT5 6 cable spool RJ45 plug and RJ45 crimper Fo...

Страница 10: ...open before mounting the Backup Interface CAUTION HEAVY OBJECT To avoid muscle strain or back injury use proper lifting techniques and if required a lifting aid ATTENTION Objet lourd Pour viter la fat...

Страница 11: ...cket Verify that the bracket is firmly attached to the mounting surface 5 Hang the Backup Interface on the bracket Figure 2 Mounting the Backup Interface 6 Insert the two supplied screws through the o...

Страница 12: ...to the left and then down to hang it on the short fin and the bolt affixed to the outer left fin Figure 3 Installing the Backup Interface 3 Mark spots for drilling on the mounting surface Figure 4 Ma...

Страница 13: ...older to the mounting surface with two screws Figure 6 Securing the conduit holder with screws 8 Tighten the conduit holder to the outer left fin with the supplied screw Tighten the screw with a torqu...

Страница 14: ...input Communication cables from inverters and external rapid shutdown switch ON OFF switch When ON enables automatic transition to backup mode When OFF enables manual control of the Backup Interface...

Страница 15: ...nd neutral bars with the bonding supplied with the Backup Interface Tighten the bonding screws with a torque of 41 lb in 4 7 N m 6 Pass the cable from the AC Loads panel through the Loads conduit 7 Pa...

Страница 16: ...nsulated or CAT5 12V power 16 AWG cable AC power 6 AWG 4 20 AWG 600V insulated cable NOTE If an auto transformer is connected to the inverter make sure to disconnect it before connecting the Backup In...

Страница 17: ...shown above If there is a short circuit jumper between the RSD terminals of the inverter remove it before connecting the RSD terminals to the Backup Interface d Reconnect the 7 pin connector to the co...

Страница 18: ...wn above Apply a torque of 22 in lb 2 N m 5 Connect the Neutral wire to the Neutral bar 6 Connect the Grounding wire to the Grounding bar Connecting the Backup Interface to an External Rapid Shutdown...

Страница 19: ...3 Remove the short circuit jumper from the 2 pin connector 4 Connect the cable to the 2 pin connector as shown above 5 Insert the 2 pin connector back into the EXT RSD port 6 Reinstall the Backup Int...

Страница 20: ...o OFF 3 Access the SetApp and select Commissioning Communication Communication Server LAN LAN DHCP RS485 1 Modbus Mutli Devices RS485 2 SolarEdge Leader ZigBee NA Wi Fi NA Cellular PCL GPIO RRCR Modbu...

Страница 21: ...ommissioning Power Control Energy Manager Backup Configuration Backup Enable After the Backup Configuration is enabled the Backup Interface is automatically configured Backup Interface Installation Gu...

Страница 22: ...ted Mode on page 22 26x7 Backup Interface thresholds error Verify correct country configuration 26xF Inverter doesn t lower AC voltage Turn off and then back on the inverter AC and DC switch 26x11 Bac...

Страница 23: ...2 Switch the inverter ON OFF P switch to OFF 3 Release the six Allen screws and remove the Backup Interface cover You can use the Allen key found at the bottom left side of the Backup Interface 4 Make...

Страница 24: ...switch of the Backup Interface to OFF 2 Switch the inverter ON OFF P switch to OFF 3 Attach the CTs to L1 and L2 wires at the service entrance point in the main service panel The arrow on the CTs must...

Страница 25: ...xternal CTs twisted pairs from the extension cable to the connectors L1 to L1 L2 to L2 11 Reinstall the Backup Interface cover and tighten it with the screws Apply a torque of 2 2 lb ft 3 N m 12 If ne...

Страница 26: ...Fault Red On Backup Interface is in the backup mode Communication with the inverter is OK Error Blinking turns on and off for the same duration Backup Interface is in the grid connected mode Off No c...

Страница 27: ...Imbalance compensation in backup operation 5000 W AC L N output voltage in Backup nominal 120 V AC L N output voltage range in backup 105 132 V AC frequency range in backup 55 65 Hz INVERTER INPUT Nu...

Страница 28: ...C part15 class B INSTALLATION SPECIFICATIONS Supported inverters StorEdge Inverter AC from grid conduit size AWG range 2 conduits 0 4 0 AC inverter conduit size AWG range 1 conduit 14 4 AWG AC generat...

Страница 29: ...r indicated on the product SetApp mobile application or on the monitoring platform or by the LEDs if there is such an indication System configuration information including the type and number of modul...

Страница 30: ......