SMI Configuration – Setup Mode
You can configure the SMI using one of the following:
. When using this option, the SMI cover is removed.
. When using this option, removing the SMI cover is not
required. This option of configuration includes a less detailed set of menus.
Configuring the SMI Using the Internal LCD User Buttons
After SMI installation, an installer may perform basic system configuration.
Configuration is done when the SMI is in Setup mode.
To enter Setup mode:
1. Turn OFF the DC from the inverter, either by turning OFF the DC breaker (if
applicable) or by turning OFF the inverter as described in its manual.
2. Turn the SMI ON/OFF switch to OFF . Wait until the voltage is safe (<50V).
WARNING!
Do not touch the DC power connections until the DC voltage is at a safe
level. Doing so may cause injury or loss of life, damage to the device and/or
danger of fire.
3. Press the Enter button for at least 5 seconds. The following message is displayed:
P l e a s e e n t e r
P a s s w o r d
* * * * * * * *
4. Use the three rightmost internal LCD user buttons to type in the following password:
12312312. The following menu is displayed:
L a n g u a g e < E n g >
C o m m u n i c a t i o n
P o w e r C o n t r o l
D i s p l a y
M a i n t e n a n c e
I n f o r m a t i o n
The SMI is now in Setup mode and all its LEDs are lit. The SMI automatically exits Setup
mode if no buttons are pressed for more than 2 minutes.
SMI-180 Installation Guide MAN-01-00157-1.1
31
SMI Configuration – Setup Mode