3. Cautions & Warnings

The following notes are CAUTIONS & WARNINGS designed to inform you of the existence of
areas of potential injury and hazard.  These notes help to prevent personal injury and fatalities.
They will also help prevent damage to the SolarAttic Swimming Pool heater, swimming pool
systems or to the house.

MAKE SURE YOU READ AND UNDERSTAND THESE CAUTIONS & WARNINGS!

- 4 -

CHILDREN CAUTION: 

SHARP EDGES ON THE SOLARATTIC POOL HEATER CAN CAUSE CUTS

OR INJURIES.  THIS IS NOT A PRODUCT THAT CHILDREN SHOULD BE ALLOWED TO TOUCH.
THEIR NATURAL CURIOSITY CAN RESULT IN INJURY OR ACCIDENT.  **KEEP ALL CHILDREN
AWAY FROM THIS PRODUCT TO PREVENT CUTS, INJURIES OR ACCIDENTS**

ELECTRICAL DANGER: 

THIS PRODUCT USES 115 VAC POWER AND CAN CAUSE A FATAL 

INJURY IF  SERVICED BY INEXPERIENCE PEOPLE.  THIS MANUAL ASSUMES THAT AN 
EXPERIENCED ELECTRICIAN IS BEING EMPLOYED.  ALL ELECTRICAL WIRING MUST BE
DONE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL ELECTRICAL CODES.

PLUMBING CAUTION: 

THIS PRODUCT REQUIRES PVC CEMENT WELDING AND THIS 

MANUAL ASSUMES AN EXPERIENCED PLUMBER IS BEING EMPLOYED.  DO NOT ACCEPT
ANY LEAKING PVC JOINTS.  DO NOT “LEARN” PVC CEMENT WELDING ON THE EXPENSIVE
POOL VALVES PURCHASED.  DAMAGE TO THE VALVES FROM POOR PVC WELDING IS NOT
COVERED BY THE MANUFACTURERS WARRANTY.  ASSEMBLE THE VALVES AND PIPES 
BEFORE ACTUAL WELDING TO MAKE SURE THE JOINTS FIT PROPERLY.  THIS INSURES
YOUR PARTS ARE READY FOR PERMANENT CEMENTING.

PLUMBING CAUTION: 

DO NOT USE DRAIN-WASTE (HOUSE SINK OR DRAIN) PVC FITTINGS

(45

°

 OR 90

°

 ELBOWS, STRAIGHT SXS FITTINGS, ETC.) ON YOUR POOL’S SUPPORT SYSTEM

RE-ASSEMBLY.  USE SCHEDULE 40 PVC OR CPVC FITTINGS.  THE DRAIN-WASTE PVC 
FITTINGS DO NOT HAVE THE SAME DEPTH OF PVC PIPE PENETRATION, WHICH COULD 
RESULT IN THE POOL’S PVC PIPE POPPING AWAY FROM THE SHORTER DRAIN-WASTE PVC
FITTING (ELBOW, ETC.). 

FIN CAUTION

: THE FINS ON THE WATER COIL ARE SHARP AND CAN CAUSE A RAZOR- LIKE

CUT IF YOUR HAND OR ARM COME INTO CONTACT WITH THEM.  TAKE APPROPRIATE CARE
DURING INSTALLATION AND DO NOT COME INTO DIRECT CONTACT WITH THE FINS OF THE
COIL.  IF THE COIL FINS ARE ACCIDENTALLY DAMAGED, THEY CAN BE “COMBED” STRAIGHT
WITH A FIN COMB [10 FINS PER INCH].

AIR MOVING ASSEMBLY CAUTION

: THE PROTECTIVE GRILLE AND OTHER PARTS OF THE

AIR MOVING ASSEMBLY, INCLUDING THE BLOWER BLADES AND MOTOR HAVE SHARP 
EDGES WHICH CAN CUT YOUR FINGER OR HANDS.  EXERCISE CAUTION WHEN HANDLING, 
REMOVING OR INSTALLING ANY PART OF THE AIR MOVING ASSEMBLY.

BLOWER CAUTION

: DO NOT OPERATE THE MOTOR WITH THE AIR MOVING ASSEMBLY 

REMOVED.  THE PROTECTIVE GRILLE IS TO PREVENT HARM WHILE THE BLOWER UNIT IS
OPERATING.  UNPLUG THE SOLARATTIC POOL HEATER DURING SERVICE AND ENSURE
THAT THE BLOWER HAS STOPPED ROTATING.

Содержание PCS3

Страница 1: ...Installation and Operating Instructions SolarAttic Solar Pool Heater Pool Convection System Three U S Patents 5 014 770 5 452 710 5 746 653 SolarAttic Model PCS3...

Страница 2: ...This page intentionally left blank...

Страница 3: ...m 6 7 Basic Plumbing Diagram 8 Power The PCS3 9 Internal Wiring Diagram 10 Float Wiring Diagram 11 Goldline GL235 Solar Control 12 Goldline GL235 Circuit Board 13 Automation Wiring Diagram 14 Goldline...

Страница 4: ...tion strikes the roof and reaches the attic through a process called conduction The SolarAttic pool heater is physically located inside the attic and then transfers this solar radiation from the attic...

Страница 5: ...wered from the actual attic peak heat transfer performance can be dramatically reduced 7 The pool water sensor can be influenced by the sun and rain Shelter the pool water sensor as much as is possibl...

Страница 6: ...VERED BY THE MANUFACTURERS WARRANTY ASSEMBLE THE VALVES AND PIPES BEFORE ACTUAL WELDING TO MAKE SURE THE JOINTS FIT PROPERLY THIS INSURES YOUR PARTS ARE READY FOR PERMANENT CEMENTING PLUMBING CAUTION...

Страница 7: ...BLE AND DOES NOT SMELL OF CHLORINE YOU HAVE THE RIGHT POOL CHEMISTRY CHECK WITH YOUR LOCAL POOL CHEMICAL DEALER IF YOUR POOL DOES NOT HAVE THESE ATTRIBUTES BUILDING CODE CAUTION INSTALL ALL EQUIPMENT...

Страница 8: ...mating pvc female fittings to the copper pipe threads we recommend using silicone sealant and allowing the joints to properly cure for 24 hours before placing them into use Do not use teflon tape Loca...

Страница 9: ...ort systems located far away from the attic can be relocated closer by extending the pool s support piping Extremely long pipe runs may require added horsepower from the pool s pump If your pump is in...

Страница 10: ...I I I IN N N N R R R RE E E ET T T TU U U UR R R RN N N N L L L LI I I IN N N NE E E ES S S S PUMP S S S ST T T TR R R RA A A AI I I IN N N NE E E ER R R R I I I IN N N NT T T TA A A AK K K KE E E E P...

Страница 11: ...Note Place the attic sensor above the PCS3 out of the air flow and at the apex or peak of the attic The discharge air of the PCS3 can cool the temperature sensor down causing erratic cycling on off of...

Страница 12: ...on this speed If the blower just hums this motor starting capacitor will have to be replaced Turn the power off remove the electrical cover panel and replace the capacitor Ensure the new capacitor is...

Страница 13: ...pret the open circuit as a cold attic and shut down the PCS3 An open float also results in a flashing check sensor red light on the Goldline GL235 solar control The PCS3 must operate in the AUTO mode...

Страница 14: ...Goldline GL235 Solar Control 12...

Страница 15: ...Goldline GL235 Circuit Board 13...

Страница 16: ...2 No connection 3 115 vac Hot Side from timer black 4 115 vac Neutral from timer white 5 115 vac Hot Side from timer to GL 235 Relay black 6 115 vac Hot Side from Relay to SolarAtttic Outlet black Ne...

Страница 17: ...15 Goldline Wiring Option 220 VAC...

Страница 18: ...llations maximum heat extraction is limited by human intervention or semi automated devices like switches or timers However heat extraction can be easily maximized and automated by way of an optional...

Страница 19: ...need to be changed Note This is also a very rare occurrence 6 Some evidence of a small amount of condensate will be present in the form of a water stain in the interior of the PCS3 base pan This is n...

Страница 20: ...amount of residual water that is trapped within the bottom of the coil The non toxic RV antifreeze available at local hardware stores dilutes any residual water and prevents winter freeze damage Winte...

Страница 21: ...ssibility of a period of one or more days when temperatures below freezing are occurring or being forecasted by prevailing weather OR you may be simply late in getting around to winterizing your pool...

Страница 22: ...e entire assembly can also be completely dismantled using only a few tools a a portable drill or electric drill b a 5 16 hex head bit c a No 2 phillips screwdriver or drill bit and d two 1 2 socket or...

Страница 23: ...e 6 Internal PCS3 blower motor thermal cutoff Wait 15 minutes for it to cool off then retry 7 Defective PCS3 power cord or plug 8 Defective Motor starting capacitor 9 Defective Motor 10 Defective Sola...

Страница 24: ...rnal limit switch needs adjusting 2 Internal cam needs adjusting 3 Internal mechanical stop needs adjusting 4 Defective valve operator Replace TEST Reverse the VOR Switch Turn it from ON1 to the ON2 p...

Страница 25: ...disconnected sensor wires 1 Poor solar weather No Sunshine 2 Pump Timer out of sync with solar energy collection time causing pool to cool too much time 3 Water flow valves to PCS3 are shut off or re...

Страница 26: ...waterfall It masks performance of PCS3 or offsets the heat gains of the PCS3 Waterfalls on a pool can have a dramatic cooling effect on pool temperature 1 Pool water temperature sensor exposed to coo...

Страница 27: ...size of the filter pump 3 Slave the filter pump to the GL235 power relay us ing an external relay as shown online and also use a minimum runtime timer This will ensure that only the minimum filtration...

Страница 28: ...nd the products they manufacture receive regular ETL safety reviews during each year to maintain product safety certifications When you buy the PCS3 you can have full confidence that the SolarAttic pr...

Страница 29: ...Single Speed Noise 62 db A weighted 67 db C weighted 10 feet Plumbing Connections 2 Male Pipe Threads Pressure Drop 4 6 PSI typical Air Flow Rate 2600 SCFM Water Flow Rate Range 15 65 GPM Optimal Wate...

Страница 30: ...They are waffled in appear ance and not straight Fin bending that has been combed with a fin tool does not affect performance and is not considered a manufacturing defect Our obligation under this war...

Страница 31: ...This page intentionally left blank...

Страница 32: ...5 West Veum Appleton Minnesota 55311 www solarattic com 2003 2016 All Rights Reserved Version 1 5 ETL Contents subject to change Original Appleton Minnesota Manufacturing Crew in 2003 Made In The U S...

Отзывы: