background image

Solar Panel Maintenance and Care

Although a well designed vehicle-mounted solar system requires minimal maintenance, it is highly
recommended to perform an inspection and cleaning of the solar panels during the warranty period.
This helps to ensure optimal system performance and reliability through a few simple steps.

Visual
Inspection

Perform a visual inspection of the solar system on a monthly basis to identify if there are
any visual defects or improper connections.

n

Check for any sharp objects on the solar panel surface.

n

Check for any signs of corrosion or burnt hotspots around the solar cell and
backsheet area.

n

Check that the solar panel is clear of any shading by any foreign material or
unwanted obstacles. Just a small amount of shade on the solar panel surface can
cause significant power output loss.

n

If the solar panel has slight discoloration over a period of usage, this is considered
normal for solar panels that use an anti-reflection coating laminate.

Cleaning
Solar
Panels

The power output of a solar panel is proportional to the amount of sunlight that reaches
the solar cells. Therefore, any build-up of dust or dirt on the surface of the solar panel will
result in a loss of power. This is a trade-off between the maximizing the power output of
the solar panel versus the cost and time to perform regular cleaning.

c

 Do not clean solar panels if there is broken plastic material or exposed wiring because

this creates a risk for electric shock.

c

 Do not step or kneel on the solar panel during cleaning.

n

Check the solar panel periodically during seasons that the vehicle is in-use. If
there is a build-up of dust or dirt on the surface of the solar panel, it is
recommended to clean it.

n

Clean the solar panel in the early morning or early evening when the solar panel
is cooler, especially in hot regions. This will reduce the risk for electrical and
thermal shock.

n

Clean using a soft cloth together with clean water and mild detergent or soap.

l

Make sure there is no soap residue remaining after cleaning.

l

Avoid using water with high mineral content that may leave deposits on
the solar panel surface.

l

Do not use abrasive materials to clean the solar panel.

l

Do not use chemicals to clean the solar panel.

l

Do not pressure wash the solar panel.

12

975-1029-01-01 Rev B

June 2022

Содержание Xantrex 784-0110

Страница 1: ...energy and quietly produce power for your vehicle s DC appliances and store energy to a battery during daylight hours The Solar Max Flex Panel base package includes the following items n one Solar Max...

Страница 2: ...t disassemble the solar max flex panel except where noted for connecting wiring and cabling See your warranty for instructions on obtaining service Attempting to service the solar max flex panel yours...

Страница 3: ...c Installation Steps 5 Safety Instructions 5 Tools and Materials 5 Solar Panel Wiring 10 Solar Panel Maintenance and Care 12 Troubleshooting 13 Specifications 13 Accessory List 15 975 1029 01 01 Rev B...

Страница 4: ...This page is intentionally blank...

Страница 5: ...codes and regulations n Disconnect all power sources n Disable and secure disconnect devices Failure to follow these instructions can result in death serious injury or equipment damage Tools and Mater...

Страница 6: ...that is readily accessible viewable and free from exposure to moisture c Plan the route and measure the lengths of cables needed to reach their connection points factoring in bends and slack d You may...

Страница 7: ...an obstruct direct exposure to sunlight l Select the mounting area carefully and mark the exact and intended location of the solar panel Failure to follow these instructions can result in physical dam...

Страница 8: ...t the 3M website Figure 4 Adhesive placement depending on surface sealing tape Forillustration purposes The solarcellsare shown asperspective only Do not applythe adhesive tape on top of the solarcell...

Страница 9: ...oute the PV cables through the roof entry point and connect the red pos and black neg PV cables to the charge controller See T3 d Connect the red pos and black neg battery cables to the charge control...

Страница 10: ...power point tracking 30A 12 24VDC 710 3024 01 b Solar panels can be configured in series parallel or a combination of both series and parallel Figure 5 Cable schematic for series Pos of first panel c...

Страница 11: ...first panel connects to Neg of next panel using branch connectors and so on and terminating with the Neg of the solar charge controller Optimized for MPPT or PWM solar charger Figure 7 Cable schematic...

Страница 12: ...he amount of sunlight that reaches the solar cells Therefore any build up of dust or dirt on the surface of the solar panel will result in a loss of power This is a trade off between the maximizing th...

Страница 13: ...light Loose or no DC cable connections Connect DC cables to the battery and solar panel and tighten terminal connections Fuse is blown Replace the blown fuse with a 30A 32V green ATC blade fuse Specif...

Страница 14: ...220 W Maximum power voltage 24 6 V Maximum power current 9 0 A Open circuit voltage 29 2 V Short circuit current 9 7 A Maximum system voltage 600 VDC Safety Class II PV Module Insulate leads and conn...

Страница 15: ...50 PV Connector Assembly Tool PN 708 0060 Mounting Hardware PN 708 0070 Remote Battery Temperature Sensor PN 708 0080 Roof Entry Cable Plate PN 708 0090 Solar and Battery Cables Starter Kit 10 AWG 20...

Страница 16: ...1 800 670 0707 1 408 987 6030 customerservice xantrex com http www xantrex com power products support http www xantrex com 975 1029 01 01 Rev B June 2022 Printed in USA...

Отзывы: