WATTrouter M - user manual 

 

 

 

 

How to fit and setup the device 

Page 1 from 79 

 

 

 

 

 

 

 

 

 

 

WATTROUTER M - USER MANUAL 

FOR MODELS: 

WATTROUTER M SSR (WRM 01/06/12 AND WT 02/10) 

WATTROUTER M MAX (WRM 01/06/12 AND WT 03/11) 

 

 

HOW TO FIT AND SETUP THE DEVICE 

Document version: 2.5 

Last revision: 1. 8. 2022 

Company: SOLAR controls s.r.o. 

 

 

Содержание WATTROUTER M MAX WT 03

Страница 1: ...device Page 1 from 79 WATTROUTER M USER MANUAL FOR MODELS WATTROUTER M SSR WRM 01 06 12 AND WT 02 10 WATTROUTER M MAX WRM 01 06 12 AND WT 03 11 HOW TO FIT AND SETUP THE DEVICE Document version 2 5 La...

Страница 2: ...t configuration 23 S Connect protocol settings 23 Description of the S Connect protocol 23 Pairing of stations to the access point 25 Cancel station pairing 26 Device pairing 26 Protocol limitations i...

Страница 3: ...o 3 all 6 loads control mode each phase independently 57 Example No 4 5 loads control mode each phase independently 59 Ethernet network configuration 61 The Local network connection settings 61 Settin...

Страница 4: ...ive loads compliant to European standards EN 61000 3 2 and EN 61000 3 3 This regulation modulates connected load s power exactly according to the available surplus energy Very short average dynamic re...

Страница 5: ...n is determined even when this load is switched on load with second priority in the same mode is switched on as well If the power output of PV plant is still increasing additional connected loads are...

Страница 6: ...to fit and setup the device Page 6 from 79 PACKAGING CONTENTS Contents of packaging 1 WATTrouter M regulator 1 WATTrouter M current sensing module 1 USB cable 1 short manual with links to this manual...

Страница 7: ...ambient temperature must be maintained within the range mentioned in chapter Technical specifications Do not place the regulator or other electronic components of this system near flammable objects W...

Страница 8: ...connect loads to the relay outputs use wires with adequate cross section corresponding with the power ratings of the connected loads To connect loads to the power triacs or SSRs again use wires with a...

Страница 9: ...current measuring input L2 from the current sensing module I_L3 electric current measuring input L3 from the current sensing module LT low tariff signal detection 0V or 5V FB1 input for connection of...

Страница 10: ...basic principles connections may be combined in various ways You may connect any number of loads to any outputs in certain cases you may remove certain phase cable from the measuring etc Figure 3 Thre...

Страница 11: ...nt branch The accuracy of measurement is reduced down to 10 in this connection because of the finite impedance of current transformer secondary winding Caution Current flow through current sensing mod...

Страница 12: ...e current sensing module Increasing of current measurement range may be done in both SSR and MAX models but we recommend WATTrouter M SSR model due to higher resolution of A D converter when current t...

Страница 13: ...r is turned off Upon completion of the installation process make sure to check thoroughly the connection of the regulator and the current sensing module Also check connection of all terminals at the b...

Страница 14: ...o so you may damage the USB interface of the regulator If the regulator is constantly connected to PC via USB interface mostly if long cable is used we strongly recommend using an USB isolator Note It...

Страница 15: ...WATTrouter M user manual How to fit and setup the device Page 15 from 79 Now the controller is fitted and ready for configuration...

Страница 16: ...cluding firmware update over the Ethernet interface You do not need to use the USB interface at all provided that the parameters of the connected LAN are the same as the default controller parameters...

Страница 17: ...er M user manual How to fit and setup the device Page 17 from 79 4 Select No not this time In the following window select Install from a list or specific location Advanced 5 Select the path to the dri...

Страница 18: ...the installation there might appear a warning about an invalid digital driver signature Just ignore it The device is registered in your system device manager as USB serial converter menu Universal Ser...

Страница 19: ...puts This can be done on the Input settings tab First you set the phase sequence and then the direction of current flows through the current sensing module a Setting up phase sequence Turn off the PV...

Страница 20: ...there is normal default current flow direction right image appears for opposite direction Note The PV inverter throughput appears exactly as the opposite because the current is anti phased with the v...

Страница 21: ...eeds the value specified in the Connected power field there is also a different solution available see the Prepend before triacs SSRs function When the load is switched on for proportional output it m...

Страница 22: ...the CombiWATT field for the relevant output output must be activated which means that the output must be assigned with the relevant priority enter the established value of the daily electric energy i...

Страница 23: ...e active at all times and the CombiWATT mode will be activated after production of PV plant comes to an end after sundown SETTING UP TIME SCHEDULES Up to 4 independent time intervals may be set for ea...

Страница 24: ...uch as the daily and total energy measured by the respective device d Output The output excitation data in the range of 0 to 1000 is transmitted where 0 means the output is switched off and 1000 means...

Страница 25: ...ice must be within range of the SC Gateway for the request to arrive If the request does not arrive and even after a longer period of time 1 minute or more and the information below is not displayed t...

Страница 26: ...the access point will continue to ignore that station CANCEL STATION PAIRING If the pairing needs to be canceled this is done in the control interface of the access point and possibly the station For...

Страница 27: ...COL LIMITATIONS IN THE WATTROUTER M The S Connect protocol has the following limitations in the device The Ethernet version of the protocol only works in station mode it is not possible to create an a...

Страница 28: ...x remove the USB cable and turn on the distribution box again Tip In order to maintain continuous monitoring the controller can be kept connected either via USB or Ethernet If you want to use permanen...

Страница 29: ...available in the WATTconfig M control software and explains their meaning Or you may use the controller web interface where the items have identical names and meanings MAIN WINDOW The main window disp...

Страница 30: ...occur when the internal DC voltage source is heavily loaded The firmware since version 3 0 checks this and eventually signals this failure This malfunction lasts for the duration of the cause and for...

Страница 31: ...d turned off by the thermostat Status output indicators inform the user about the reason for switching or possibly about the reason for output restriction There are following indicators a Blue it is d...

Страница 32: ...ion Text may contain maximum of 16 characters in ASCII encoding Sunrise today it displays time of sunrise for today This time is calculated directly in the controller based on the actual calendar date...

Страница 33: ...e WATTrouter M SSR in a facility where the main circuit breaker is rated up to 3x400A In this case you have to buy external current transformers with ratio 400A 5A Connect short cut their secondary te...

Страница 34: ...ly for controlling the output of resistive thermal appliances and in case of SSR outputs it requires the connection of external power semiconductor relays SSRs This mode can further increase the flick...

Страница 35: ...hain for that phase Note that for triac outputs in proportional mode this option has no meaning as no 3 phase load can be connected to triac output directly in this mode Put one third of nominal input...

Страница 36: ...ost all available surplus energy even if heating elements are connected to relay outputs For example if you are using a three phase heating element Example 1 heating element 3x2 kW connected and confi...

Страница 37: ...tion is used this value gives the minimum power for the connected load The output will not be activated unless available surplus energy exceeds this threshold Nonzero value can be useful e g for propo...

Страница 38: ...tput that is selected in this field Example Consider a three phase pool heater operated in the control mode of each phase separately Here we need to ensure the operation of the pool water circulation...

Страница 39: ...tate as described in chapter Other settings tab TIME SCHEDULES TAB On this tab you may set time schedules for individual outputs Up to 4 independent time intervals may be set for each individual outpu...

Страница 40: ...tly Asked Questions section of the manufacturer s website M to S shortcuts for weekdays The time schedule will be active only on checked days LT If you mark this field the time schedule additionally r...

Страница 41: ...offset value applies for each phase independently The lower more negative the power offset is the more power consumption from grid is avoided in transitional statuses as well as in stable statuses wh...

Страница 42: ...nly used to obtain the IP address of the DNS server the device will use only the DHCP inform request or the DHCP discover request c all DHCP is used for complete network setup Note that in this mode t...

Страница 43: ...determine its IP address The IP address is written to the controller when the configuration is next written Since firmware version 1 5 there is no need to use this feature IP is detected primarily fr...

Страница 44: ...raphic location Latitude enter the latitude in degrees here The value is used to calculate the sunrise time and therefore values specified in degrees are precise enough Longitude enter the longitude i...

Страница 45: ...he Consumption and Surplus fields The IL1 3 inputs are fixed here For any phase and any category consumption surplus production of PV it is now possible to select any input that measures or captures i...

Страница 46: ...it is terminated b Access Point AP the unit acts as an access point that controls the operation of remote stations and their pairing This mode is not supported in WATTrouter M c Station STA the unit a...

Страница 47: ...pe in the station table For example if all 6 stations are occupied and all are of the same type eg Ethernet then the response will usually be 6 times longer than the response of one station if we cons...

Страница 48: ...phase independently summary data are simply the sum of the fields from all 3 phases b Sum of all phases summary data are updated continuously from immediate results In this control mode summary data a...

Страница 49: ...ing into history after midnight LOG TAB This tab displays error and warning log For example the system displays detected communication errors Since firmware version 3 0 there is also a listing of up t...

Страница 50: ...to fit and setup the device Page 50 from 79 Save saves configuration to PC hard drive Reset to defaults loads default configuration settings in WATTconfig you have to write it then to the controller E...

Страница 51: ...etworks where you must switch between two IP addresses New profile may be created by pressing the New button The new profile stores the current IP address and UDP port settings Created profiles may be...

Страница 52: ...ified in the chapter Measured parameters and statuses Flashes regularly in the following way long long short DC source overload Proceed according to instructions specified in the chapter Measured para...

Страница 53: ...th these parameters represent approximately 1 5 kWh If you use 160 l of hot water and you take into account heat losses the daily supply of electric power is approximately 8 6 kWh Boiler is connected...

Страница 54: ...until the assumed supplied energy did not exceed the energy specified in the limit field This allows you to heat up water for evening use provided that during morning and afternoon hours the boiler wa...

Страница 55: ...is not sufficient amount of sunshine available the system will switch back to the low tariff The motor should not be running at night between 23 00 and 5 00 not to disturb people during night this als...

Страница 56: ...motor runs approximately 6 hours and therefore it applies only if the daily energy counter exceeds 1 6 kWh The second time schedule restricts operation of the motor between 23 00 and 5 00 without any...

Страница 57: ...relay No 2 Requirements are the same as in example No 2 1st heating coil with 2nd priority SSR 1 Connect the following to L3 phase auxiliary contact with 1st priority triac No 2 operating as a relay...

Страница 58: ...WATTrouter M user manual How to fit and setup the device Page 58 from 79 Time schedules are the same as in example No 2...

Страница 59: ...witches for respective outputs or by deactivating them in the software The heating pump draws power of 1 3 kW and it is supplied only with the surplus energy or manually outside of the WATTrouter devi...

Страница 60: ...WATTrouter M user manual How to fit and setup the device Page 60 from 79 Time schedules are the same as in example No 2...

Страница 61: ...ll be accessible Make sure that the address does not collide with other devices in your local network For example if the IP address of your router is 192 168 2 1 set it to 192 168 2 10 provided that t...

Страница 62: ...e following text describes a sample Internet connection configuration using a regular broadband router Edimax BR 6204Wg M See the below On the NAT Settings tab check the field Enable NAT module functi...

Страница 63: ...ng AJAX XML technology and therefore you have to allow JavaScript Monitoring the controller activity and configuring it may also be implemented into any superior control system capable to send or pars...

Страница 64: ...t switched externally 0 inactive 1 active TOT 0 TOT timer status of the relay on delay timer TFT 0 TFT timer status of the relay off delay timer T 0 T output test 0 inactive 1 active EX 0 EX private a...

Страница 65: ...to 2 L3 M 0 M 3f mode 0 none to 3 max L1 L2 L3 Po 2 00 Po connected output power in kW PM 2 00 PM maximum output power in kW PN 0 00 PN minimum output power in kW only for PWM function PI 500 PI PWM...

Страница 66: ...TSH time server hostname TSIP TSIP time server IP address DT 0 DT digital sensor type 0 DS18S20 1 DS18B20 LTI 0 LTI low tariff input 0 none 1 LT etc DFT 1 DFT default tab 0 Input settings to 5 Statist...

Страница 67: ...mode for triac 1 output 1 activate 0 deactivate similarly for remaining outputs when test mode change is required for them UN admin UN username for authorization mandatory item UP 1234 UP password for...

Страница 68: ...n kWh SDH1 0 00 SDH1 consumption normal tariff phase L1 in kWh SDL1 0 00 SDL1 consumption low tariff phase L1 in kWh SDP1 0 00 SDP1 production phase L1 in kWh similarly for remaining phases L2 and L3...

Страница 69: ...kWh yesterday similarly for the 2th to 31th last day stat_month 10 GET stat_year xml By sending this HTTP request you will obtain the annual statistics from the controller Structure of returned data...

Страница 70: ...e Check whether green LED PWR is on and the regulator is powered Computer is not properly connected with the controller Check the USB network cable connection try using different network cable or try...

Страница 71: ...these errors increases further Overloaded Ethernet Your local network or Internet connection is temporarily out of order overloaded with other transfers etc Try to reconnect later or ask a network exp...

Страница 72: ...is an unsupported impulse signal Use only device with S0 impulse output whose signal carries information about the measured energy and has a minimum impulse width of 1 ms Signal parameters are describ...

Страница 73: ...The system detected error status Follow instructions in the LED statuses chapter When the available surplus energy is decreased the triac SSR output with higher priority is switched off earlier than...

Страница 74: ...writing the history into EEPROM Cannot pair units via Ethernet using the S Connect protocol The units do not have S Connect activated Activate S Connect on all units one unit must be access point AP a...

Страница 75: ...t dissipation Should you discover a defect which cannot be repaired according to instructions specified in the Troubleshooting chapter contact your distributor applies both to warranty and post warran...

Страница 76: ...l max 40 mA MAX model max 125 mA Triac outputs 230 V 50 Hz max 10 A 2300 W only resistive load with cos 1 Protection Fuse for semiconductor protection Relay outputs 230 V 50 Hz max 10 A 2300 W it is r...

Страница 77: ...wires are acceptable but they reduce the accuracy approx by 0 2 per 2m Distance of the regulator and solid state relay 10 m Working position Any Mounting Regulator DIN 35mm or wall mounted using 2 sc...

Страница 78: ...from 79 RECYCLING After the product life is over the product may be disassembled recycled or disposed of at a safe dumpsite Legal regulations regarding electronic waste treatment have to be observed...

Страница 79: ...is declaration relates is in conformity with the following directives standards and other normative documents provided that it is installed maintained and used in application for which it was made in...