background image

SERVICE/REPAIR

RECOMMENDED BATTERY SPECIFICATIONS

1.  Size:  Group 31, 900-1200 CCA, AGM 
2.  Use battery with 3/8” threaded studs.

3.   Using a high quality battery will extend charger and wiring life. Battery acid and petroleum resistant wiring is 

used in this unit. Battery fluid level must be checked  every 30 to 45 days if you replace the original battery 

with non-AGM batteries.

BATTERY REPLACEMENT

See Figure 1

REMOVING OLD BATTERIES

1.   Remove front top panel by removing (8) #8 Phillips screws securing panel.  Remove bottom front panel by 

removing (3) top and (3) bottom #8 Phillips screws (2 middle side screws are false screws –DO NOT try to 

remove).

2.  Disconnect cables and wires from batteries. Label for easier reconnection.  Move cables out of way.

3.  Remove the nut from the left side of the AMPS gauge and disconnect red wire.

4.   Disconnect the two fast on connectors of the power cord wires from charger.  Remove green power cord wire 

from charger by removing 6-32 nut. 

5.   Remove charger from unit by removing top (5) #8 Phillips screws from back panel (3 bottom screws are 

false 

screws – DO NOT try to remove). Lift out panel and charger. Set aside.

6.   Remove front and rear hold-down bars by removing (4) 1/4-20 bolts with 7/16” sockets or wrenches. Set aside 

for later use. DO NOT touch hold-down across battery terminals, as arcing will occur.

7.  Remove upper rear battery by lifting battery up, turning and sliding it out rear opening of unit.

8.  Remove lower front battery by lifting battery up, turning and sliding it out rear opening of unit.

INSTALLING NEW BATTERIES

1.   Slide first battery in through rear opening, turning battery so that its vent faces the front of unit. Then set 

battery on lower platform of battery stand.

2.   Slide second battery in through rear opening, turning battery so that its vent faces the front of unit. Then set 

battery on upper platform of battery stand.

3.   Install rear hold-downs, then front hold-downs, using (4) 1/4-20 bolts.  DO NOT touch hold-downs across 

battery terminals, as arcing will occur.

4.  Insert back plate with charger onto the unit and re-fasten the (5) #8 x 1/2” screws securing it into place.
5.  Connect red wire from Charger #1 (upper charger) to the AMPS gauge, replace the nut and tighten.
6.   To left side of rear battery (Battery #2, NEG Terminal) connect the black wire from Charger #2 (lower 

charger), Cable from Negative side of 12 Volt quick connect, and Negative jumper cable with attached black 

wire from the right side of VOLTS gauge. Apply nut and tighten.

7.   To right side of rear battery (Battery #2, POS Terminal) connect the red wire from Charger #2 (lower charger) 

and cable from Positive side of Common Quick Connect with handle. Apply nut and tighten.

8.   To left side of front battery (Battery #1, NEG Terminal) connect the black wire from Charger #1 (upper 

charger) and cable from Negative side of Common Quick Connect with handle. Apply nut and tighten.

9.   To right side front battery (Battery #1, POS Terminal) connect the cable from the Positive side of the 12 Volt 

quick connect and Positive Jumper Cable with attached red wire from the right side of AMPS gauge. Apply 

nut and tighten.

Содержание HT1224AGM

Страница 1: ...RATING UNIT WARNING WARNING 12 24 VOLT MODELS Never hook up a 12 Volt DC power source to a 24 Volt DC vehicle This will grossly overcharge the 12 Volt power source and generate flammable gasses that m...

Страница 2: ...use Always follow the specific instructions in this manual and on the SOLAR Jump Starter each time you jump start using the SOLAR Jump Starter All lead acid batteries car truck and boat produce hydrog...

Страница 3: ...risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion 5 Remove personal metal items such as rings bracelets necklaces and...

Страница 4: ...receiving so you will have maximum power for your jumping needs 1 Unwrap AC power cord from unit and plug into 120VAC outlet 2 Charger will read internal battery status and apply the proper charge ne...

Страница 5: ...Connect POSITIVE RED clamp from unit to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK clamp to vehicle chassis or engine block away from battery last Note Do not connect clamp to ca...

Страница 6: ...tery by lifting battery up turning and sliding it out rear opening of unit INSTALLING NEW BATTERIES 1 Slide first battery in through rear opening turning battery so that its vent faces the front of un...

Страница 7: ...batteries AGM for AGM batteries 13 Plug in Power Cord to charge the batteries The AMPS gauge will register the proper charge rate being applied to the batteries Internally both chargers will have a re...

Страница 8: ...change outlet Check continuity of plug pins replace plug See figure of unit to check wiring connections Short across studs on gauge to see if charger comes on replace gauge Replace charger Possible C...

Страница 9: ...caused by repairs made by an unauthorized person mishandling modifications normal wear unreasonable use or signs of battery acid corrosion from improper use or storage or damage to the SOLAR Commercia...

Страница 10: ...ent sur le SOLAR chaque utilisation Toute batterie au plomb acide produit un gaz hydrog ne qui pourrait exploser avec violence en pr sence de flammes ou d tincelles Ne fumez pas n utilisez pas d allum...

Страница 11: ...de de la batterie dans les yeux sur la peau ou sur les v tements 2 R agissez toujours rapidement en cas de contact avec de l acide Si de l acide est projet sur la peau ou les v tements lavez les imm d...

Страница 12: ...le cordon lectrique C A ou la prise incluse ils ne sont pas compatible avec la prise de courant faites installer une sortie appropri e par un lectricien qualifi Cette unit sert sur un circuit de 120 v...

Страница 13: ...urraient causer des dommages aux personnes 5 Brancher la pince rouge POSITIVE de l unit la borne POSITIVE position P sans prise de terre de la batterie Brancher pince noire N GATIVE au ch ssis du v hi...

Страница 14: ...utilisation ult rieure NE touchez PAS aux bornes de la batterie car cela entra nerait un arc lectrique 7 Retirez la batterie sup rieure arri re en la soulevant vers le haut en la tournant et en la fa...

Страница 15: ...rs m le double femelle simple sur le chargeur n 1 chargeur sup rieur 12 Assurez vous que le commutateur de ventilation de la batterie mont sur le double chargeur correspond au type de batterie install...

Страница 16: ...eliez les goujons de la jauge pour voir si le chargeur fonctionne remplacez la jauge Remplacez le chargeur R glez la position 12 volts CAUSE POSSIBLE Les connexions rapides ne sont pas attach es ensem...

Страница 17: ...E EN VERTU D UNE RUPTURE DE GARANTIE EXPRESSE OU TACITE D UNE N GLIGENCE D UNE RESPONSABILIT CIVILE D LICTUELLE AU SENS STRICT OU TOUTE AUTRE BASE JURIDIQUE Cette garantie s applique toute personne de...

Страница 18: ......

Страница 19: ......

Страница 20: ...ual Model HT1224AGM Commercial Jump Starter This product can expose you to lead which is known to the State of California to cause birth defects or other reproductive harm and Vinyl Chloride Styrene a...

Отзывы: