SpaceControl
1. FEATURES
Ajax Space Control keyfob is used for activation /
deactivation of Ajax security system, for partial
activation and also as an alarm button.
2. SPECIFICATIONS
3. COMPONENTS
SpaceControl keyfob, battery CR2032, manual
SPECIFICATION
MEANING
Buttons' quantity
4
Alarm button
available
Radio signal power
20 mW
Radio-frequency
range
868 MHz (Europe); 915 MHz
(USA)
Maximum distance
between keyfob and
central unit
1000 m (3300 ft) (open area)
Power supply
CR2032 battery
Power supply voltage 3V
Battery life
up to 5 years
Operation
temperatures range
from -20°С (-4°F)
to +50°С (+122°F)
Operation humidity
up to 90%
Dimensions
65x37x10 mm (2.5x1.45x0.4 in)
5. KEYFOB USE FOR SECURITY SYSTEM ARM-
ING/DISARMING
5.1 It is required to check if the keyfob’s buttons are
functioning.
5.2 After pressing the button, the keyfob via the ra-
dio channel sends an appropriate encoded signal to
the central unit. The keyfob uses a special wireless
connection technology for messages encoding and
anti-fraud protection.
5.3 The central unit handles the signal from the keyfob
and turns on/off the security mode. Due to the two-
way connection with the central unit, the keyfob re-
ceives the confirmation of the signal coming to the re-
ceiver. In case activation/deactivation signal for some
reason was not received, the keyfob blinks momen-
tarily 4 times. If the light indicator lights for 1 second
when any button is pressed, it means that the signal
was successfully transmitted to the receiver.
4. SETTING-UP PROCEDURES
4.1 Before using the keyfob, it is required to regis-
ter it with the Ajax security system.
4.2 In order to register the keyfob, it is necessary
to switch the Ajax security system’s receiver to
«Add Device» mode (the receiver’s manual ex-
plains how to accomplish it). During the receiver’s
functioning in «Add Device» mode, it is necessary
to press simultaneously the buttons “1” and “4”
(PICTURE 1), and then the keyfob will be regis-
tered in the security system.
In case the registration failed and the keyfob was
not registered, it blinks with 4 lights, 6 times once
in a second. It blinks the same way after pressing any
button in case the keyfob is not registered with the se-
curity system.
4.3 Once the keyfob registered with the receiver, it is
ready for operating.
PICTURE 1.
Space Control keyfob’s buttons
1
3
5
2
4
5.4 In order to arm the security system, it is nec-
essary to press the button “1” (“Armed mode ac-
tivation”). When the button is pressed, the indi-
cator’s light is on for approximately 1 second and
then turns off.
5.5 In order to disarm the security system, press
the button “3” (“Disarmed mode activation”). Af-
ter pressing the button, the indicator lights for
one second and then switches off.
5.6 Button “2” is used to partially arm security
system, when not all the sensors are turned to
security mode but the defined part of them (for
further details, consult the receiver’s manual).
For example, a part of the house, additional build-
ing or garage.
5.7 The keyfob had a special alarm button ”4”.
When it is pressed, the security system’s central
unit is turned to “Alarm” mode immediately. (For
further details, consult the receiver’s manual).
ATTENTION
!
A maximum distance of 1000 m (3300 ft) be-
tween the keyfob and the receiver is men-
tioned as a comparison with other devices.
This distance was found as a result of open
area tests. Connection quality and distance
between the keyfob and the receiver can
vary depending on installation location,
walls, compartments, bridgings, as well as
the thickness and constructional material.
Coming through the obstacles, signal loses
power. For example, distance range between
the sensor and receiver divided with two re-
inforced concrete bearing walls constitutes
approximately 30 m (98.4 ft).
1 – “Armed mode activation” button
2 – “Partially armed mode activation” button
3 – “Disarmed mode activation” button
4 – “Alarm” button
5 – Light indicators of the keyfob functioning
Solar
Plus
Ajax
SpaceControl
Solar