45
December 2020
|
Solar Stik
®
, Inc.
System Setup and Operation Manual for the Solar Stik G-BOSS E Light HPS
PRELIMINARY
i Connect PRO-Verter to 120 VAC Loads (Optional)
Connect 120 VAC loads to the PRO-Verter AC outputs on the right side of the PRO-Verter. Connect
loads of no more than 20 A for one (1) outlet and no more than 25 A total between the two (2) outlets.
Turn off load power switches to prevent power draw during System setup.
Figure 36. PRO-Verter AC power output ports
j Connect Loads Requiring Regulated 28 VDC Output (Optional)
REGULATED
28VDC OUPUT
Connect loads that require regulated 28 VDC output. The maximum output from this connection
is 7.8 A or 220 W. A custom cable is required; contact Solar Stik for details. Turn off load power
switches to prevent them from drawing power during System setup. Do not attempt to power the
PDU or Tower from this connection.
Figure 37. PRO-Verter Regulated DC power output port
220 W Max Output