MOTOR STOP ADJUSTMENT INSTRUCTIONS 

 

PLEASE NOTE THAT THE DROP HAS ALREADY BEEN PRE-SET TO THE REQUIRED DIMENSION.  

THESE INSTRUCTIONS ARE TO MAKE 

ADJUSTMENTS

ADJUSTMENTS

ADJUSTMENTS

ADJUSTMENTS

 ONLY. 

 

220 - 240 Volt  50/ 60Hz  80 Watt  

 

 

Insert the hex-key supplied, into the relevant hex socket. Turn the key in the direction of the

 

+

 

to increase the rotation of the roll tube or in the direction of

 

-

 

to reduce the number of times 

the roll tube rotates. 

 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Low Voltage - 24 Volt  DC Motors 
 

 
 
 
 
 
 
 
 
 
 

 'STOP' POSITION 
        AT TOP 
 

 

'STOP' POSITION 

      AT BOTTOM

 

 

ADJUST  THE  'STOP'  POSITIONS 
USING  THE  SUPPLIED  HEX-KEY.  IF 
THE

 

MOTOR  IS  FITTED  TO  THE  R/H 

SIDE

 

THE SAME ADJUSTERS SET THE

 

SAME 'STOP

POSITIONS

 

STOP

 

POSITION

 

 

ADJUSTERS

 

THE STOP POSITION ADJUSTERS 
HAVE ARROW SHAPES TO SHOW 

THE DIRECTION THEY CONTROL 

MOTOR IS SHOWN IN POSITION USING A 
FACE FIX MOTOR BRACKET WHICH CAN 

ALSO BE USED FOR TOP FIXING 

Содержание Casslte

Страница 1: ...h a NON ABRASIVE dry duster is all that is required Finger prints grease and most stubborn marks on film blackout lyverscreen and fibreglass fabrics can be carefully removed with white spirit and a soft cloth followed by a further wiping over with a soft non abrasive cloth dipped in clean soapy water If any type of film or fabric becomes very dirty it can be carefully wiped over with a soft non ab...

Страница 2: ...evel FITTING INSTRUCTIONS FOR INSTALLING ELECTRICALLY OPERATED NON CASSETTE MOUNTED BLINDS AND SCREENS FACE FIX MOTOR BRACKET TOP FIX MOTOR BRACKET FACE FIX PIN END BRACKET TOP FIX PIN END BRACKET NON CASSETTE CABLE SUPPORT SYSTEM 1 The brackets supplied are UNI FIX and are suited to all methods of fitting including TOP fix FACE fix and SIDE FIX 2 Decide EXACTLY where the screen blind is to be fit...

Страница 3: ...f the to increase the rotation of the roll tube or in the direction of to reduce the number of times the roll tube rotates Low Voltage 24 Volt DC Motors STOP POSITION AT TOP STOP POSITION AT BOTTOM ADJUST THE STOP POSITIONS USING THE SUPPLIED HEX KEY IF THE MOTOR IS FITTED TO THE R H SIDE THE SAME ADJUSTERS SET THE SAME STOP POSITIONS STOP POSITION ADJUSTERS THE STOP POSITION ADJUSTERS HAVE ARROW ...

Страница 4: ...individual requirements which include group and remote control Basic Mains Voltage AC 3 Position Hard Wired Switch Other switches can be used depending on individual requirements which include group and remote control AC 3 Position Hard Wired Switch Connections DC 3 Position Rocker Switch Connections TO CHANGE THE MOTOR DIRECTION REVERSE THE TWO WIRES ...

Страница 5: ...Doc ELE16PH33A Page 5 AC MOTOR GROUP CONTROL WITH SWITCH 4 MOTOR RELAY UNIT 3 2 AC MOTOR RELAYS ARE ALSO AVAILABLE ...

Страница 6: ...Doc ELE16PH33A Page 6 DC MOTOR GROUP CONTROL WITH SWITCH GPS 1020 TRANSFORMER UP TO 10 MOTORS CAN BE CONNECTED CONTROLLED BY ONE GPS 1020 AN INFRARED SENSOR CAN ALSO BE ADDED FOR REMOTE CONTROL SWITCH ...

Страница 7: ...Doc ELE16PH33A Page 7 AC MOTOR INDIVIDUAL CONTROL WITH INFRARED SENSOR SWITCH THE IRT 803 REMOTE ALLOWS GROUP INFRARED CONTROL IR3 IR3 SWITCH SWITCH ...

Страница 8: ... 8 DC MOTOR GROUP CONTROL WITH INFRARED SENSOR SWITCH CAN ALSO BE ADDED SEE PAGE 5 IRS 300 INDIVIDUAL CONTROL WITH INFRARED CAN BE ACHIEVED BY USING ONE IRS 300 SENSOR PER SCREEN AN ALTERNATIVE 24V DC TRANSFORMER IRS 300 ...

Страница 9: ...Doc ELE16PH33A Page 9 DC IRS 300 INFRARED SENSOR NOTE UP TO 3 MOTORS CAN BE WIRED TO A SINGLE IRS 300 SENSOR ...

Страница 10: ...Doc ELE16PH33A Page 10 AC IR3 INFRARED SENSOR THE IR3 SENSOR IS EQUIPPED WITH A FEMALE PHONE PLUG WHICH ALLOWS THE EASY CHANGE OF THE CABLE WITH A PHONE PLUG ...

Страница 11: ...te then please follow the following programming instructions if the unit has not already been set up WARNING IF YOU USE THE IRT803 IT IS NECESSARY TO LOCK THE RECEIVERS THAT ARE NOT BEING PROGRAMMED BY OPERATING THEM IN EITHER UP OR DOWN DIRECTION THEY WILL BE LOCKED FOR 3 MINUTES AND IT IS IMPOSSIBLE TO ENTER IN THE PROGRAMMING MODE BY THE IRT803 TO UNLOCK THEM GIVE A STOP ORDER Programming the I...

Страница 12: ...H33A Page 12 FURTHER INFORMATION More detailed wiring options can be found in each component instructions which are enclosed in the box If you have any questions please contact the Retailer in the first instance ...

Отзывы: