![Solar Bollard Lighting SBL SERIES Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/solar-bollard-lighting/sbl-series/sbl-series_general-installation-manual_1313416002.webp)
© 2003 - 2016 Key Wholesalers Pty Ltd t/a Solar Bollard Lighting- All rights reserved
SBL SERIES MOUNTING TYPE INSTALLATION INSTRUCTIONS
-
BURIED IN GROUND POLE
-
BEFORE YOU INSTALL:
Dial before you Dig
Ensure Anchor Bolts are through pole base/s.
STEP 2A -
Dig hole to depth for pole length being
used as per below instructions:
Note:
A larger concrete foundation maybe required for very
poor (sandy) soil
Pole Length
Hole
Depth
Insert
Pole
Hole
Diameter
1140mm 45’
400mm 16’ 300mm 12’ 300mm 12’
2840mm 112’
600mm 25’ 500mm 20’ 300mm 12’
3640mm 143’
900mm 36’ 800mm 31’ 300mm 12’
STEP 2B -
Pour concrete into the hole
STEP 2C -
I
nsert pole into concrete ensuring the
internal of the pole is also filled with concrete. Use
spirit level to ensure pole is set correctly.
STEP 2D -
Cure concrete before re-attaching the
SBL Series light head. Cover the pole top with plastic
or similar.
RETURN TO PREVIOUS PAGE STEP 3:
Light Head Re-Attachment Instructions
-
GROUND MOUNT POLE
-
BEFORE YOU INSTALL:
(not included in kit)
Mounting Bolts, M12 (1/
2’) Washer, 4 x M12 (1/2’) Nuts.
We recommend using security fasteners to prevent theft.
STEP 2A
-
Check with spirit level mounting surface
is flat as pole must sit level for solar recharging.
STEP 2B
-
Mark out holes on mounting surface to
suit base plate.
STEP 2C
-
Drill or core hole to take an M12 (
1/2’)
thread or other securing device
STEP 2D
-
Install your mounting threads.
ENSURE
MINIMUM
of
30mm (1.2’) of actual thread is protruding
above surface. Base plate thickness is 12mm (0.5
’).
STEP 2E
-
Place the base plate over the bolts and
secure pole with your locking nuts. Use spirit level
while tensioning to ensure pole is set level.
RETURN TO PREVIOUS PAGE STEP 3:
Light Head Re-Attachment Instructions
-
WALL MOUNT INSTALLATION
-
BEFORE YOU INSTALL:
(not included in kit)
Mounting Bolts, M12 (1/2’) Washer, 4 x M12 (1/2’) Nuts.
We recommend using security fasteners to prevent theft.
Note: Lower power models can achieve the lower mounting
position without full directional sun all day.
STEP 2A
-
Mark holes on surface to suit wall plate.
STEP 2B
-
Drill or core hole to take an M12 (1/2’)
securing device then install your mounting threads.
ENSURE MINIMUM of 30mm (1.2’) of actual thread is
protruding above concrete. Wall plate thickness 10mm
(0.4’)
STEP 2C
-
Place plate over the bolts and secure plate
with your locking nuts.
RETURN TO PREVIOUS PAGE STEP 3:
Light Head Re-Attachment Instructions
All dimensions in millimetres
All dimensions in millimetres