Bunsen Air - Installer Manual
6 |
P a g e
4
Bunsen Air Controller Specifications
Bunsen Air
Solar Assisted Heat Pump
Casing:
Cold rolled steel
Chassis Base:
Galvanized steel
Water Pipe-work Connections:
3/4 inch
Compressor:
Sealed hermetically and covered with a layer of insulation to prevent heat loss and
absorb unnecessary vibrations
Refrigerant:
R134a- Tetra-fluoro-ethane, global warming potential (GWP) 1430
Condenser:
High performance steel shell & tube heat exchanger
Water Pump:
Dynamic conversion circulation pump
Compact design with low noise level, suitable for indoor installations
Performance
Unit
Rated Power Output
w
400
Max. Duel Panel Thermal
Performance Output
w
2690
Water Temperature
°C
53 (default setting, maximum temperature 60°C)
Dimensions and Weight
Casing
mm
1.2
Chassis Base
mm
1.5
Height
mm
400
Width
mm
500
Depth
mm
260
Weight
kg
39
IP Number
-
IP 21
Connections
Water inlet
inch
3/4
Water outlet
Inch
3/4
Refrigerant inlet
Inch
3/8
Refrigerant outlet
Inch
¼
Power supply
V / Hz
220 - 240 / 50
Specifications
Operating current (Max.)
A
5
Operating Temperature
°C
- 8 to +40
Refrigerant charge (R134a)
g
1400
Sound Level
dB(A)
Equal or less than 41
Max working pressure
Bar
(Water side) 8
*Figure as per EN16147:2017, EU812/2013, ISO9806:2013
Bunsen Air Controller Dimensions
Dimensions
Front View
Isometric diagram
Side View