Special instructions for heat-light
combination units with WSS and FUE2
• Refer to the separate manual of the heat-light combination unit for installation
and operating instructions.
• Your heat-light combination unit is already equipped with an integrated remote
control (WSS, LTDS, LFDS).
• The light module can be switched on and continuously dimmed using the re-
mote control.
• Additionally, the 2 radiant heaters can be switched on using the remote control
and the heat output adjusted in steps.
Heat-light combination units 2x 1000W / 2x 1400W:
• Both radiant heater are internally jointly connected to a WSS wireless receiver.
• Light and heat can be programmed separately from each other. However it is
not possible to program and control the two radiant heaters separately.
• The connection to the heat-light combination unit is provided by a 3-phase
power supply (230 V to neutral). However only 2 phases are required.
• For separate programming of light and heat, one current phase is supplied to
the part of the heat-light combination unit that is to be programmed.
Heat-light combination unit 2x 2000W:
• Both radiant heaters are separately connected to a WSS wireless receiver.
• Light and each radiative heater can be programmed separately from each
other.
• 3 phases are required for the power supply for these product variants.
• For separate programming of light and heat, one current phase is supplied to
the part of the heat-light combination unit that is to be programmed.