background image

Reference Manual 

Solaira Malibu 

Post Kit with Alpha H1 Heaters 

MAL 45240     208/240V  4.5kW (3 × 1.5kW) 
MAL 60240     208/240V  6.0kW (3 × 2.0kW) 

INFORESIGHT CONSUMER PRODUCTS INC.

 

125 Traders Blvd. E Unit # 4, Mississauga, Ontario L4Z 2H3 

Tel: 905-568-7655  -  Fax: 905-568-7521 

Email: [email protected]  -  Website: www.solairaheaters.com 

I M P O R TA N T   -   S AV E   T H E S E   I N S T R U C T I O N S   F O R   F U T U R E   R E F E R E N C E  

E

N

 

SHORTWAVE INFRARED HEATERS WITH POST & INCOMING TERMINAL BOX KIT 

FOR: INDOOR USE - COMMERCIAL AND INDUSTRIAL ONLY

 

OUTDOOR USE - RESIDENTIAL, COMMERCIAL AND INDUSTRIAL 

FOR USE IN NON-HAZARDOUS AREAS ONLY 

Post and weatherproof terminal box rain tested to: 
UL 2021 4th Edition by CSA Montréal Lab. 
 
Alpha H1 Heaters fitted are approved to: 
CAN.CSA-C22.2 No. 46-13 & UL 2021 3rd Edition.

 

247748 

Содержание Malibu MAL 45240

Страница 1: ...ters com Website www solairaheaters com IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE EN SHORTWAVE INFRARED HEATERS WITH POST INCOMING TERMINAL BOX KIT FOR INDOOR USE COMMERCIAL AND INDUSTRIA...

Страница 2: ...rom the front of the heater and keep them away from the sides and rear 4 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating...

Страница 3: ...mains cables away from the body of the heater and heater heads which will get hot during use 17 Do not touch the heater during operation as the body becomes hot and could causes burns Particular atten...

Страница 4: ...nt rating WARNING Wiring procedures and connections should be in accordance with the National Electric Code NEC and local codes WARNING If the supply cable becomes damaged it must be immediately repla...

Страница 5: ...ER FIXING KIT 1 OFF BASE PLATE 1 OFF BODY POLE 2 OFF APPROVED WEATHERPROOF TERMINAL BOX ASSEMBLY INCLUDING CERAMIC BLOCKS STRAIN RELIEF GLANDS 1 OFF CURVED ARM TUBE 3 OFF JOINING INSERT 6 OFF INFILL P...

Страница 6: ...nd plain washer but don t fully tighten yet Fig 1 Fig 2a Fig 2b ASSEMBLY CAUTION CAUTION CAUTION CAUTION The following procedure should be carried out by a qualified person only in accordance with the...

Страница 7: ...rms come together as shown in Fig 5 with the lid on the top Note The nuts on the two side strain relief glands can be removed to provide better access to the screw slots Fig 5 Fig 4 5 Using and M4 scr...

Страница 8: ...to drop the nut down the tube Using a 13mm A F socket tighten the nut fully by gaining access through the hole in the top of the tube as shown in Fig 7b Repeat with the other two heaters Fig 7a Fig 7b...

Страница 9: ...nt length Fig 9 Fig 10a Fig 10b 10 Crimp 4mm ring terminals Fig 10a to the wires ready for connection Fig 10b 11 Connect the ground wires to the ground post with copper clamps serrated washers and M4...

Страница 10: ...ted as shown in Fig 12 Fig 12 13 Fit a zip tie around the curved arms at the base plate to keep them together when the assembly is moved in the installation stage on the next page It is recommended so...

Страница 11: ...nal box lid can be removed now for installation The M8 20 button head socket screws and spring washers should be removed and retained while the zip tie should be left around the curved arms tubes unti...

Страница 12: ...split washer behind the head of the screw on all faces M8 SPRING SPLIT WASHER 3 OFF M8 20 BUTTON HEAD SOCKET SCREW 3 OFF 4 Slide a body pole with joining pieces fitted onto the three joining pieces of...

Страница 13: ...he heads of the screws M8 SPRING SPLIT WASHER 3 OFF M8 20 BUTTON HEAD SOCKET SCREW 3 OFF 6 Connect the mains supply cable to the connector block and earth post as shown using ring terminals and keepin...

Страница 14: ...tion cover can now be fitted by ensuring the lip on the edges go over the infill pieces and lining the slots up with the holes in the curved arms Fix in place with M4 screws and shake proof washers 9...

Страница 15: ...15 of 20 Ref No 043477 EN Rev A GENERAL SIZES...

Страница 16: ...Finger marks will burn into the lamp emitters quartz glass causing premature failure MAINTENANCE CAUTION Switch off unit from the mains supply by locking off the breaker before replacing a lamp emitt...

Страница 17: ...rect replacement lamp emitter quoting model type and rating from rating label It is important that you read through the lamp emitter replacement procedure before commencing 1 Ensure the heater and lam...

Страница 18: ...eflector Fig F and lift the side reflector up and away from the heater Repeat at the opposite end to remove other side reflector 8 The lamp emitter wires should be pulled out of the side slots Fig G a...

Страница 19: ...d Replace both ends side reflectors and their screws ensuring the lamp emitter is held firmly then fit any other parts Fig H 9 The lamp emitter can now be removed away from the heater leaving it ready...

Страница 20: ...eaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2019 INFORESIGHT CONSUMER PRODUCTS INC Ref No 043477 EN Issue No...