1.      When  wall  mounting,  securely  fasten  the  L-shaped  wall 
         brackets  to  the  mounting  surface  using  both  of  the  fixing 
         holes  in  the  short  part  of  the  bracket  (see  Fig.  D  for  
         mounting  hole  centres).  Please  refer  to  Table  1  for        
         recommended  positioning  of  the  heater.  Please  note.  wall 
         fixings  are  not  supplied.  They  should  be  selected  to     
         substantially  support  the  weight  of  the  installation.  If  in 
         doubt  contact  a  professional  for  advice!  When  hanging 
         from  a  ceiling  two  equal  length  and  gauge  chains  are      
         required  and  should  be  selected  with  fixings  that  are    
         adequate  to  hold  the  weight  of  the  heater.  Again,  if  in 
         doubt contact a professional for advice! 
 
2.      The heater should be mounted with the terminal box at the 
         bottom of the heater when being wall mounted. 
 
3.      When wall mounting, fix in the required angular position by 
         tightening the fixing bolts on the brackets at the rear of the 
         heater as shown in Fig. C. The heater should face directly 
         down when hanging. 
 
4.      Secure the supply cable so it is not resting on the body or 
         obstructing the air-vents. 
 

Always  isolate  the  heater  from  the  mains  supply  when     
adjusting the position.

 

DRILLING HOLE TEMPLATE DIMENSIONS FOR WALL MOUNTED BRACKETS 

Fig. B 

Always  allow  the  heater  to  cool  before  attempting  to          
reposition/move.  Never  attempt  to  move  the  heater  while  it 
is switched on! 

 

Observe  the  minimum  safe  distance  between  the  heater 
body and inflammable surfaces and objects when mounting. 

 

Please refer to Table 1 for the recommended positioning of 
the heater with regards to minimum distances. Do not install 
the heater in a corner! 

 

Keep out of the reach of children. 

Fig. C 

TERMINAL 

BOX 

Fig. D 

S

E

E

 T

A

B

L

E

 1

 F

O

R

 M

IN

IM

U

M

 

D

IM

E

N

S

IO

N

S

 

Содержание Alpha H2SALPHAH2-20240

Страница 1: ...000 4000W EN INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com IMPO...

Страница 2: ...nd unattended 5 Do not operate any heater with a damaged cord or after the heater malfunctions has been dropped or damaged in any manner Return heater to authorized service facility for examination el...

Страница 3: ...t the heater IMPORTANT INSTRUCTIONS IMPORTANT INSTRUCTIONS IMPORTANT INSTRUCTIONS IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS...

Страница 4: ...om the floor as specified below in the specification Table 1 3 Ensure that the heater has been securely fastened in its final mounting position 4 WARNING This appliance must be grounded and hard wired...

Страница 5: ...0 6000 6750 9000 9000 12000 Current Amps per Emitter 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 Total Current Amps of Unit 7 2 8 3 10 8 12 5 14 4 16 7 14 4 16 7 21 6 25 0...

Страница 6: ...ic power supply before working on circuit wiring to prevent electric shock CAUTION Please observe the minimum safe distance between the heater body and any inflammable surfaces CAUTION When the electr...

Страница 7: ...being wall mounted 3 When wall mounting fix in the required angular position by tightening the fixing bolts on the brackets at the rear of the heater as shown in Fig C The heater should face directly...

Страница 8: ...joined they should only be hung from a ceiling on chains do not wall mount Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on...

Страница 9: ...ten at this point 7 Position the third heater so it s parallel to the second 8 Line up the bars of the first heater with the brackets of the second heater they should go on the inside faces like heate...

Страница 10: ...ION CAUTION CAUTION CAUTION Switch off unplug the heater from the mains supply when mounting or adjusting the heater position Fig F 1 Please refer to Table 1 for recommended positioning of the heater...

Страница 11: ...from the mains to the heater or heater assembly power before any attempts are made to replace the emitter Contact your distributor for the correct replacement emitter quoting model type and rating fro...

Страница 12: ...g K 6 At the front of the heater gently remove the wire guards by prizing them away from their locating holes at one end of the heater case Fig L and pull out of opposite end Fig L Fig N 7 Remove the...

Страница 13: ...ut of the side slot see Fig P and the emitter can be lifted up completely The wire can then be gently pulled forward so that it also comes out from behind the reflector 13 10 The emitter can now be re...

Страница 14: ...WALL MOUNTED CONFIGURATION AT A GLANCE 1 x Alpha H2 Unit 14...

Страница 15: ...3 x Alpha H2 Units CHAIN HANGING CONFIGURATIONS AT A GLANCE 1 x Alpha H2 Unit 2 x Alpha H2 Units 15...

Страница 16: ...655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2013 INFORESIGHT CONSUMER...

Отзывы: