solaia SL375 THRU Скачать руководство пользователя страница 22

 

22

Solaia Residential Cast Iron Boiler Warranty

 

First Year Limited Warranty for Solaia Residential Cast Iron Water Boilers 
 
Boyertown Furnace warrants that its residential cast iron water boilers are free from defects in material and workmanship under normal 
usage for one year from the date of original installation. If any parts are found to be defective in manufacture during this one-year period, 
Boyertown Furnace Company will supply a replacement for the defective part. 
 
The Limited Lifetime warranty for the cast iron heat exchanger of its residential water boilers includes the heat exchanger only, not 
component parts.  
 
Boyertown Furnace Company warrants that the cast iron heat exchanger of its residential water boiler is free from defects in material and 
workmanship under normal usage during the lifetime of the original owner at the original place of installation. If any sections are found 
to have a manufacturing defect in materials or workmanship Boyertown Furnace will repair or, at its option replace them. 
 
Exceptions and Exclusions 
1.

 

The limited lifetime warranty covers only the cast iron heat exchanger assembly. The burner, jacket, controls and other equipment 
furnished by Boyertown Furnace Company but purchased from other manufacturers shall be limited to their warranties, if any. 

 
2.

 

This warranty does not cover expenses for removal or reinstallation. The homeowner will be responsible for the cost of removing 
and reinstalling the defective part or its replacement and all labor and material connected therewith. Replacement material will be 
invoiced to the distributor in the usual manner and will be subject to adjustment upon proof of defect. 

 
3.

 

This warranty in no way can be considered as a guarantee of workmanship of an installer connected with the installation of the 
Solaia cast iron or as imposing on Boyertown Furnace Company liability of any nature in the installation which liability is expressly 
disclaimed. 

 
4.

 

This warranty will not be applicable if the boiler is used or operated over its rated capacity or installed for uses other than home 
heating; or is not maintained in accordance with Boyertown Furnace Companies recommended or accepted good practice as 
determined by industry standards. 

 
5.

 

This warranty will not be applicable if the boiler has been damaged as a result of being improperly serviced or operated, including 
but not limited to the following: operated with sufficient water; allowed to freeze: subjected to flood conditions: or operated with 
water conditions and or fuels or additions which cause condensation, unusual deposits, or corrosion in or on the cast iron sections. 

 
6.

 

This warranty applies only to boilers installed in the United States. 

 
7.

 

In order for this warranty to be effective a) The boiler must have been installed in a single or a two family residential dwelling. This 
warranty doe not apply to boilers installed in apartments or commercial or industrial installations. b ) The boiler must have been 
assembled in strict compliance with the installation instructions furnished with the boiler. c) Boiler sections must not have been 
damaged in handling during shipment or installation. 

 
8.

 

The remedy for breach of this warranty is expressly limited to the repair or replacement of any part found to be defective under 
conditions of normal; and the remedy for incidental, special or consequential damages or loss such as loss of the use of the 
materials, inconvenience or limitation of incidental or consequential damages so the above limitations or exclusions may not apply 
to you. 

 
9.

 

The warranty is lieu of all others, and any and all express or implied warranties (including, without limitation any implied warranties 
of merchantability or fitness for a particular purpose), are expressly limited in duration to the period of the warranty as previously 
stated herein. Some state do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to 
you. 

 

This warranty does not extend to anyone except the first purchaser at retail and only when the boiler is in the original installation 
 

Implied warranties of fitness for a particular purpose and merchantability shall be limited to the duration of the express warranty. 
Boyertown Furnace Company expressly disclaims and excludes any liability for consequential or incidental damages for breach of any 
express or implied warranty. 
 
For prompt warranty service, notify the installer who in turn will notify Boyertown Furnace distributor from where the boiler was 
purchased. If this action does not result in warranty service, contact the Boyertown Furnace Customer Service Department, P.O. Box 100, 
Boyertown, Pa. 19512, with details in support of the warranty claim. Alleged defective part or parts must be returned through trade 
channels in accordance with the Boyertown Furnace Company’s procedure currently in force for handling returned goods for the purpose 
of inspection to determine cause of failure. Boyertown Furnace will furnish the new parts to an authorized Boyertown Furnace distributor 
who in turn will furnish the parts to the heating contractor who installed the boiler. If you have any questions about the coverage of this 
warranty, contact Boyertown Furnace Company at the above address. This warranty gives you specific legal rights, and you may also 
have other rights which vary from state to state.  

Содержание SL375 THRU

Страница 1: ...ATOR S MANUAL SL375 THRU SL7175 CAST IRON BOILERS Keep these instructions with the boiler at all times for future reference BOYERTOWN FURNACE CO PO Box 100 BOYERTOWN PA 19512 1 610 369 1450 www boyert...

Страница 2: ...erty damage Your oil fired boiler is designed to burn No 1 and No 2 heating oil only Never use gasoline or a mixture of gasoline and oil Do not store gasoline or other flammable vapors and liquids in...

Страница 3: ...n Tanks Venting Systems 8 Chimney Venting Direct Venting Burner Installation 13 Oil Tank and Piping 13 Gas Piping 14 Wiring 14 Swing Door 17 Opening the Door Closing the Door Door Hinge Reversal Opera...

Страница 4: ...19 1 4 19 1 4 22 3 4 22 3 4 26 1 4 26 1 4 29 3 4 33 1 4 Supply Outlet Height 25 3 8 25 3 8 25 3 8 25 3 8 25 3 8 25 3 8 25 3 8 25 3 8 Return Outlet Height 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 4 1...

Страница 5: ...all times Ventilation of boiler room must be adequate enough to provide sufficient air for combustion When a boiler is located in an unconfined space in a building of conventional frame or masonry con...

Страница 6: ...wn it may be assumed that wood louvers will have 20 25 free area and metal louvers and grills will have 60 75 free area Louvers and grills shall be fixed in the open position or interlocked with the b...

Страница 7: ...BY TECHNICALLY QUALIFIED SERVICEMEN SOLAIA BOILERS HAVE A MAXIMUM OPERATING PRESSURE OF 58PSI NOTE If normal operating pressures are greater than 30psi please contact the manufacturer for required tri...

Страница 8: ...in to conform to code standards Discharge piping from the relief valve must be piped to a drain or must terminate 6 above the floor to eliminate damage to the structure or personal injury It must not...

Страница 9: ...he boiler should comply with applicable building codes such as NFPA 211 An additional listed lining may be required to reduce transient low draft during startup and acid water condensation during cycl...

Страница 10: ...he chimney must be made above the bottom of the chimney to avoid blockage Vent piping should extend just into the chimney far enough to expel flue gasses Inserting the vent piping too far into the chi...

Страница 11: ...system must conform to the following guidelines See figure on following page a The vent terminal shall not be less than 3 feet above any forced air inlet to the house b The vent terminal shall not be...

Страница 12: ...ANCE TO COMBUSTIBLE MATERIALS FROM THE DOUBLE WALL INSULATED VENT PIPING IS 2 CONSULT NFPA 31 FOR REDUCED CLEARANCES The air intake must be installed to the air inlet collar on the combination vent ho...

Страница 13: ...correct nozzle is properly installed in the burner as shown in the preliminary burner settings and that the burner electrodes are adjusted as per the burner manual When using the Beckett AFG Carlin EZ...

Страница 14: ...00 242 000 180 100 000 255 000 Note 1 Using 0 06 Specific Gravity Gas and a pressure drop of 0 3 of Water Column 2 To obtain equivalent length of pipe add total length of pipe plus 3 for each 90o elbo...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...the upper brackets must be removed from the holes in the right side and placed in the holes on the left side of the upper brackets 4 The aquastat immersion well must be moved to the upper left rear t...

Страница 18: ...et aquastat high limit between 180o F and 200o F 12 Turn service switch on Burner should start On one pipe fuel system only you may have to bleed the oil system To bleed attach a clear plastic tube to...

Страница 19: ...2 80 2 0 150 PSI 12 0 11 0 Beckett CF375 1 35x45o B 9 0 1 00 150 PSI 12 0 11 0 Preliminary Gas Burner Settings Boiler Burner Gas Type Orifice Manifold Pressure Air Setting CO2 Draft Flue SL375 Carlin...

Страница 20: ...eezes are toxic substances 11 Check the piping system for leaks and repair as required This will prevent water turnover with consequent risk of scale formation and corrosion in the boiler room 12 Chec...

Страница 21: ...5 552815 552815 552815 11 1 Drain Valve 3 4 327998 327998 327998 327998 327998 12 1 Street Elbow 3 4 328002 328002 328002 328002 328002 13 1 Relief Valve 3 4 Female 570181 570181 570181 570181 570181...

Страница 22: ...osits or corrosion in or on the cast iron sections 6 This warranty applies only to boilers installed in the United States 7 In order for this warranty to be effective a The boiler must have been insta...

Страница 23: ...spill switch Oil Burner Operation Burner Model __________________ Nozzle _______GPH _______Deg ____Type_______ Burner Pump Pressure ______________ Fuel filter and fuel lines installed and inspected as...

Страница 24: ...___________________________________________ Purchaser s Address ________________________________________________________________________ _______________________________________________________________...

Отзывы: