CONNECTIONS – ELECTRICAL
30
HOT SENSOR LEAD
House the hot sensor lead at the water heater in the flexible conduit provided and secure the conduit in
the cut out on the tab located behind the upper front cover. Connect the hot sensor cable to the hot
sensor cable connector located on the tab behind the upper front cover. Secure the hot sensor lead to
the water heater jacket to prevent possible damage.
TEMPERATURE SETTING
For reasons of safety and economy, we advise the thermostat of the in-series booster water heater be
set at the lowest temperature that will provide sufficient hot water during periods when boosting is
required. Solahart recommends the thermostat is set at 60
°
C to maximise solar contribution. Discuss
the thermostat setting requirements with the householder.
AUXILIARY PUMP
The auxiliary pump, if installed, must be wired to the control board. Refer to
“Auxiliary Pump – Electrical
Connection”
on page 33.
WIRING DIAGRAM