4. Test Mode
4.1. Autotest
4.1.1. Autotest Steps
1. Press and hold SW5.
Autotest follows a predefined flowchart in order. Unlike
service autotest, autotest automatically skips to next step
upon completing one. The steps of the test are as follows:
Step1:
The drain pump is checked.
Step2:
Motor ramps to max spin speed while valves are activated
in order.
Step3:
Motor stops, both valves are activated simultaneously.
Step4:
The motor turns to right. Also, dryer valve is activated.
Step5:
The motor turns to left.
Step6:
Both valves are activated. (Water intake for heating)
Step7:
Washer NTC is checked.
Step8:
Washer Heater is checked.
Step9:
Dryer resistance I and I&II are checked.
Step10:
Dryer NTC is checked for 2sec.
Step11:
Fan is checked.
In case of no failure test ends after this step and “End” is
displayed. In case of an error detection EXX and error
definition will pop up on display. (where XX is the error
number 1 to 10 )
Please see following autotest chart for details.
2. While pressing SW5, turn PR to 1
st
position
(Cotton). Wait 3 seconds and release SW5. During
test “AU” is visualized on display.
3. When autotest is finished, END screen is
visualized.
Содержание D4 Series
Страница 1: ...Manuel de service Séries D4 ...
Страница 37: ...9 Wiring Diagram ...