background image

 

 

Getting started  

   

 

Read  this  quick  guide  before  you  unpack,  install  and 
operate mobiLink.  

   

Unpacking your mobiLink 

1.

 

Take  the  device  and  the  accessory  parts  out  of  the 
box. 

2.

 

Save box and packing material for future use. 

3.

 

Verify  that  the  following  items  are  contained 
undamaged:  

 

mobiLink device 

 

USB cable (2m) 

 

red and black testing cables with clamp 

 

3 AA batteries 

     

Setting up your mobiLink 

1.

 

Depending  on  your  use  case  (configuration/ 
parameterization)  download  the 

MOBILINKdtm

  or 

the 

Communication  Configuration  Tool

  from  the 

product website. Scan the QR code on the back page 
for quick access. 

2.

 

Double-click the setup file to start the installation. 

3.

 

Select the installation language. 

4.

 

Follow the install wizard instructions

.

 

5.

 

Read the 

User Guide

 available for download. 

   

Startup and Operation 

Insert  the  batteries,  switch  on  the  mobiLink  and  wait  5 
seconds  until  the  device  has  started.  The  operation  of 
mobiLink requires the use of  management tools like FDT 
frame applications or configuration tools on Windows PCs 
or tablets or smartphones.  

   

See  the 

User  Guide

  for  safety  requirements  and  details 

on  how  to  set  up  a  USB  and  Bluetooth  communication 
and how to configure the fieldbus and HART connection. 

   

During  startup  mobiLink  tries  to  verify  the  operation 
mode  against  the  connected  fieldbus.  If  fieldbus 
terminals are connected to an operating 4-20 mA link this 
will compromise the analog  process value. Make sure to 
use the correct connections and mode. 

   

Safety 

mobiLink must be operated by qualified personal only. To 
ensure the safety of personnel and equipment, mobiLink 
must  be  used  as  intended  and  in  accordance  with  local 
laws  and  regulations.  See  also  the 

User  Guide

  for  safety 

requirements and regulations. 
 

Transport and Maintenance 

Remove  the  batteries  for  transport  from  the  device  to 
ensure  that  mobiLink  is  mechanically  secured  against 
being  switched  on  inadvertently.  Periodically  wipe  the 
housing  with  a  damp  cloth.  Do  not  use  abrasives  or 
solvents. Do  not clean the device inside hazardous areas! 
mobiLink  does  not  contain  user  serviceable  parts.  No 
modifications  or  repair  on  the  device  are  allowed.  The 
operator  is  responsible  for  the  transportation  and 
maintenance of the product. 

   

Explosion protection 

mobiLink has been developed for use in hazardous areas, 
classified  as  Zone  1/Zone  2.  It  is  approved  for  explosion 
group  IIC  and  temperature  Class  T4  or  higher.  Make  sure 
that you use mobiLink only in compliance with local safety 
requirements  for  installation  of  electrical  equipment  in 
explosive atmospheres. See the 

User Guide

 for details. 

   

 

  

 

Do not use the USB communication mode inside 
hazardous areas! 

 

Declaration of conformity 

This product meets all requirements of the applicable FCC 
and FM standards.  

  

 

   

Bluetooth 

This product has been tested and approved for Bluetooth 
wireless  communication  in  the  following  regions  and 
countries:  

  

 

    

 

 

 
  

   

 

USA 

 

Canada 

   

   

Certification of conformity

 

This  product  is  FM  and  FCC  certified  and  was  found  to 
comply

 

with the standards and requirements indicated by 

the following marks: 

 

  

 

   

 

     

         

                   

      

 

 

 

  

 

 

                              

                    

 

    

 

    

 

Отзывы: