Enable or disable reactive functions.
16. Set Power Derate
Enable or disable the power derate function of the inverter, and set the derate
ratio.
17. Reflux Power
Enable or disable the anti-reflux function of the inverter, and set the reflux
power.This function need to be used with external CT, please refer to this manual
4.5 RS485, CT, inverter logic interface connection for details.
18. MPPT Scan
Shadow scanning, when the component is blocked or abnormal, causing
multiple power peaks, by enabling this function, the peak point of maximum power
can be tracked.
19. Start Time
Startup time and recovery reconnection time can be set.
20. Set ElecMeter
Enable or disable meter functions.
21. Logic interface
Enable or disable logical interfaces. Please refer to this manual 4.5 RS485, CT,
inverter logic interface connection for details.
22. Set Power Ratio
Set generation ratio.
(B) “Event List” Interface as below:
Event List is used to display the real-time event records, including the total
number of events and each specific ID No. and happening time. User can enter
Event List interface through main interface to check details of real-time event
records, Event will be listed by the happening time, and recent events will be listed
in the front. Please refer to below picture. Press “Back” and “Down” to turn the
page in standard interface, then enter into “2.Event List” interface.