Sofar solar 10K-15KTL-G2 Скачать руководство пользователя страница 2

SOFAR 10K~15KTL-G2

User manual

SOFAR 10K~15KTL-G2

User manual

SOFAR

 

10000TL-G2  ;  SOFAR

 

12000TL-G2  ;  SOFAR

 

15000TL-G2

ADD:401, Building 4, AnTongDa Industrial Park, District 68,XingDong Community, 
         XinAn Street, BaoAn District, Shenzhen, GuangDong.P.R. China

Notice

This manual contains important safety instructions that must be followed during installation 
and  maintenance  of  the  equipment.  The

 

product

 

you

 

purchase

 

is

 

restricted

 

by

 

SOFAR

 

SOLAR

'

s

 

commercial

 

invoice

Your

 

product

 

may

 

do

 

not

 

cover

 

the

 

full

 

characteristics

 

or

 

functions

 

described

 

in

 

this

 

document

SOFAR

 

SOLAR

 

does

 

not

 

state

/

assure

 

the

 

content

 

of

 

this

 

document

 

unless

 

there

 

is

 

special

 

contract

 

agreement

.

Save these instructions!

This manual must be considered as an integral part of the equipment, and must be available 
at  all  times  to  everyone  who  interacts  with  the  equipment.  The  manual  must  always 
accompany the equipment, even when it is transferred to another user or field.

Copyright Declaration

The copyright of this manual belongs to Shenzhen SOFARSOLAR Co., Ltd. Any corporation or 
individual should not plagiarize, partially copy or fully copy it (including software, etc.), and 
no  reproduction  or  distribution  of  it  in  any  form  or  by  any  means.  All  rights  reserved. 
SOLARSOFAR  reserves  the  right  of  final  interpretation.  This  manual  is  subject  to  change 
according  to  user ’s  or  customer ’s  feedback.  Please  check  our  website  at 
http://www.sofarsolar.com for latest version.

Danger  indicates  a  hazardous  situation  which,  if  not  avoided,  willresult 
in death or serious injury.

Warning  indicates  a  hazardous  situation  which,  if  not  avoided,  could 
result in death or serious injury.

Caution  indicates  a  hazardous  situation,  if  not  avoided,  could  result  in 
minor or moderate injury.

Attention indicates there are potential risks

.

 If fail to prevent, may lead 

to equipment cannot run normally or property damage.

It also can be some tips to use this product, it can help you to solve some 
problems and save you time.

Danger

Warning

Caution

Attention

Note

Содержание 10K-15KTL-G2

Страница 1: ...odel SOFAR 10K 15KTL G2 2021 03 17 ADD 401 Building 4 AnTongDa Industrial Park District 68 XingDong Community XinAn Street BaoAn District Shenzhen GuangDong P R China Email service sofarsolar com Tel 0510 6690 2300 Web www sofarsolar com ...

Страница 2: ...is transferred to another user or field Copyright Declaration The copyright of this manual belongs to Shenzhen SOFARSOLAR Co Ltd Any corporation or individual should not plagiarize partially copy or fully copy it including software etc and no reproduction or distribution of it in any form or by any means All rights reserved SOLARSOFAR reserves the right of final interpretation This manual is subje...

Страница 3: ... 51 52 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 10 1 Standard warranty period 10 2 Extended warranty period 10 3 Invalid warranty clause 52 52 52 DRMs Functions Symbols Safety instructions and warnings 2 Protection units Interface and Dimensions 3 4 3 Packing Materials Intended grid types ...

Страница 4: ... has IP65 Electrical positive and negative Be care of electrical polarity 1 2 Safety instructions and warnings Operator must follow bellowing safety instructions when he installs 10K 15KTL G2 series inverter incorrect operation may cause property loss equipments damage or personal injury 1 Inverter can be installed only by professional electrician or electrical engineer according to local standard...

Страница 5: ...L G2 Sofar 10K 15KTL G2 1 DC Switch 2 Vent valve 3 6 DC connector DCV C 7 WIFI GPRS DCV A 8 DRM0 DCV A 9 DRM5 8 External digital inputs DCV A 10 11 RS485 DCV A 12 AC output connector DCV C 2 2 Interface and Dimensions SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 3 4 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 6: ... C Ground fault detecting When ground fault happens inverter will stop generation automatically and the GFI red LED will be on to inform customer D Over temperature de rating When temperature is higher than internal setting inverter will derate the power automatically E Over voltage de rating When MPPT point is higher than 850V inverter will derate the power automatically F Over current protection...

Страница 7: ... 15KTL G2 3PCS 3PCS 3PCS 3PCS 3PCS 6PCS 7 8 M6 Sofar10K 15KTL G2 Sofar10K 15KTL G2 3 2 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 3 1 Packing Materials 3 2 Tools 1PCS 6pin terminal blocks 12 ...

Страница 8: ...far 10K 15KTL G2 Installation position requirements 1 It should be easy to cut off the power supply 2 The wall should have enough strength to support inverter 3 Can not be touched by child SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 3 3 9 10 ...

Страница 9: ...Figure3 3ManySofar10K 15KTL G2installation 11 12 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual ...

Страница 10: ...DC switch is in OFF status 2 Check if the grid voltage and frequency are in correct range 3 If the PV panel is thin film panel a transformer 1 25 times as inverter capacity should be added at AC side 4 PE cable should be thicker than 4mm and reliable M6 Screws OT Terminal Screw diameter 6mm M6 Threaded hole SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 4 1 Step 1 Step 2 Step 3 Step...

Страница 11: ...ee phase output inverter it complies with related on grid standard and safety requirements AC cable installation steps A part cable length 30 50mm B part cable length 3 5mm Isolation cover and terminals can not be exposed water proff cover A Crimp each core cable to OT terminal KST RNBL5 4 is recommended after fixing use isolation tape to cover exposed part of OT except O part Connect OT terminal ...

Страница 12: ...Sofar 10K 15KTL G2 Sofar10K 15KTL G2 Sofar 10K 15KTL G2 4 6 4 7 4 8 4 9 17 18 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 4 3 ...

Страница 13: ...INAL TERMINAL Sofar10K 15KTL G2 4 10 4 11 4 12 19 20 The distance between WIFI and Ethernet router should be less than 100m SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual According to the WIFI serial number user can register remote monitoring account for Sofar 10K 15KTL G2 on http home solarman cn withRS485 ...

Страница 14: ...10K 15KTL G2 4 3 4 13 4 13 4 15 4 14 4 15 4 16 21 22 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 4 4 ...

Страница 15: ...4 18 23 24 SOFAR 10K 15KTL G2 User manual SOFAR 10K 15KTL G2 User manual 4 5 DRMs Functions 4 5 1 10 15KW G2 have five TTL input and one 5V Power output witch provided the DRMs function The Ports are RG 0 CL 0 DRM1 5 DRM2 6 DRM3 7 DRM4 8 and GND 5V as shown below ...

Отзывы: