SOFAR 1.1K~3.3KTL-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 58 -
ID56
PvIsoFault
The insulation
resistance is too low
Check the insulation resistance between the
PV array and earth(ground), if a short circuit
occurs, rectify the fault.
ID57 OverTempFault_
Inv
The inverter temp is
too high
Ensure the installation position and
installation method meet the requirements of
Section 3.4 of this user manual.
Check whether the ambient temperature of
the installation position exceeds the upper limit.
If yes, improve ventilation to decrease the
temperature.
ID58 OverTempFault_
Boost
The Boost temp is
too high
ID59 OverTempFault_
Env
The environment
temp is too high
ID65
Unrecover
HwAcOCP
The grid current is
too high, and has
cause unrecoverable
hardware fault
ID65-ID70 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5 minutes,
then turn ON the “DC switch”. Check whether
the fault is rectified. If no, please contact
technical support.
ID66
Unrecover
BusOVP
The bus voltage is
too high, and has
cause unrecoverable
fault
ID67
Unrecover
IacRms
Unbalance
The grid current is
unbalance, and has
cause unrecoverable
fault
ID68
UnrecoverIpv
Unbalance
The input current is
unbalance, and has
cause unrecoverable
fault
ID69
UnrecoverVbus
Unbalance
The bus voltage is
unbalance, and has
cause unrecoverable
fault
ID70
Unrecover
OCPInstant
The grid current is
too high, and has
cause unrecoverable
fault
ID71
UnrecoverPv
ConfigSetWrong
Incorrect input
mode
Check the input mode(parallel mode/
independent mode) setting of inverter according
to Section 6.3 (C) 6.Input Mode of this user
manual, If it’s incorrect, change it according to
Section 6.3 (A) 10.Set Input mode of this manual
ID74
Unrecover
IPVInstant
The input current is
too high, and has
cause unrecoverable
fault
ID74-ID77 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5 minutes,
then turn ON the “DC switch”. Check whether
the fault is rectified. If no, please contact
technical support.
ID75
Unrecover
WRITE
EEPROM
The EEPROM is
unrecoverable
ID76
Unrecover
READEEPROM
The EEPROM is
unrecoverable
ID77
Unrecover
RelayFail
Relay has happen
permanent fault