SODECA UPM/EC Скачать руководство пользователя страница 5

 
 
 

 

 

  EN 

1.  Start 

All fans produced by 

SODECA

, hereinafter 

the manufacturer

, and the full line of accessories, have been manufactured in 

accordance with the strictest standards in relation to quality assurance, systems and production processes. 
Their  project,  testing,  manufacture  and  control  structure  has  been  configured  in  line  with  EU  standards  and  regulations, 
especially in reference to current safety standards. 
The materials used in our fans, and the standardised components of which they are made meet the same standards and, 
when so required, are backed up by the corresponding quality certificates. 

 

The Original Manual was written in Spanish. 
The manufacturer reserves the right to make modifications without prior notice.  
All the documentation in this manual is the property of the manufacturer, and its total or partial reproduction is prohibited. 

2.  Product Definition 

UPM/EC:

  Mobile  air  purifying  units,  designed  for  cleaning  and  purifying  indoor  air  and  eliminating  odours  in  any  type  of 

room. 

IMPORTANT

: This product is not suitable for use in explosive environments or for fire safety. 

3.  General Information 

• 

Always check the products received. 

• 

After unpacking the equipment, it must be checked to make sure that it is not damaged. Damaged products must 
never be installed. 

• 

This equipment must not be used for purposes other than those for which it was designed; it must only operate 
under the conditions described in this manual.  

• 

In the event of a defect or malfunction, this must be reported to the authorised representative, with a description of 
the problem, in order to coordinate its return or possible repair. 

• 

Before  starting  up  the  equipment,  it  is  important  to  ensure  that  the  safety  and  installation  instructions  in  this 
document have been read 

4.  Transportation, storage and handling 

• 

Always hold the equipment at the points provided for this. Do not lift it by the electrical cables, connection boxes, 
or the air inlets or outlets. 

• 

Before installation, store the equipment in a clean, dry place, protected from inclement weather. 

5.  Safety 

• 

CAUTION!

 Electrical power must be removed from the unit prior to opening the inspection covers to access the 

UVc lamps if installed; otherwise, these lamps could cause damage to the eyes and skin. 

• 

If  a  UVc  lamp  breaks,  ventilate  the  compartment  for  30  minutes  and  remove  the  lamp  pieces,  preferably  while 
wearing protective gloves. 

• 

Do not disassemble or modify the equipment. This could negatively affect the equipment or even cause accidents. 

• 

Do not put your fingers or any objects into the protective grilles on ducts, inlets or outlets. If this were to occur, 
immediately disconnect the equipment's power supply.  

• 

Never use a damaged power cable. 

• 

Do not perform equipment inspection or maintenance without first checking the following: 

o

 

That the equipment has been disconnected from the electrical supply. 

o

  That all its components are at rest. 

• 

The equipment must not be operated unless it has been properly installed and the inlets and outlets have been 
protected. 

In designing and manufacturing the various Series of 

the manufacturer's

 Fans and Extractors, Hazard Elimination has been 

taken into account, in order to meet the conditions for Integrated Safety. 
When  their  configuration  and  manufacturing  processes  permit  this, 

the manufacturer

  directly  incorporates  the  most 

appropriate  Safety  Devices.  If  the  conditions  for  installation  or  use  mean  that  these  devices  cannot  be  incorporated  at 
source, all additional safety accessories are available for implementation when the equipment is installed and before it is 
put into service. 
 
 
 
 
 
 

Содержание UPM/EC

Страница 1: ...Code 1276550 Doc Num 0000021532 11 06 2020 www sodeca com UPM EC ES Manual del Usuario User manual EN...

Страница 2: ...Fig 1 Fig 2 Fig 3 Rotate the tabs and remove the filter...

Страница 3: ...Fig 4 Fig 5 Fig 6 Fig 7...

Страница 4: ...380 480V 50 60Hz 3Ph 36 2990 3250 165 Recommended surface with 3 meters high local The values of the Radiated Noise Level are in dB A measured at 1 5 meter and at maximum flow rate Qmax Fig 10 Filter...

Страница 5: ...ty and installation instructions in this document have been read 4 Transportation storage and handling Always hold the equipment at the points provided for this Do not lift it by the electrical cables...

Страница 6: ...h current regulations The equipment s earth connection must be connected 7 Operation and adjustment Basic functions The regulator has 4 buttons ON OFF MODE UP and DOWN Note If the backlight is turned...

Страница 7: ...lter change press ON OFF As confirmation that the operating time has been reset is displayed on the screen and the system returns to the normal mode of operation A few seconds after ON OFF is pressed...

Страница 8: ...lluminated Manual mode Operation based on whether on off is selected and if manual setpoint is selected Time programming mode Operation based on the programmed time Programming period 1 start and end...

Страница 9: ...ed maximum voltage range 6 0 V to 10 0 V by default 10 0 V P4 UVc lamp control range 0 to 1 by default 0 0 UVc lamp disabled 1 UVc lamp enabled operation based on UVc lamp on off MODE button P5 Direct...

Страница 10: ...EN Time programming mode displays...

Страница 11: ...The impeller must be cleaned at least once a year with caution in order to not affect its balancing The fan filters must be preferably changed every 6 months of usage Fig 3 and 4 or when indicated by...

Страница 12: ......

Страница 13: ...DQUARTERS Sodeca S L U Pol Ind La Barricona Carrer del Metall 2 E 17500 Ripoll Girona SPAIN Tel 34 93 852 91 11 Fax 34 93 852 90 42 General sales comercial sodeca com Export sales ventilation sodeca c...