mod.
JUMBO 13
- man. rev. 00
page
1
of 24
Manual of SODASTREAM Professional SRL Unipersonale. No reproduction allowed without previous authorization by the owner.
EN
Страница 1: ...mod JUMBO 13 man rev 00 page 1 of 24 Manual of SODASTREAM Professional SRL Unipersonale No reproduction allowed without previous authorization by the owner mod JUMBO 13 EN...
Страница 2: ...nimum requirements 9 Cooler connection 10 Power mains connection 10 Connection to water mains 10 Connection of CO2 tube 11 Use 11 First start up 11 Regulate the pressure of water from the mains 12 Reg...
Страница 3: ...cording to the instructions Warning Keep all packaging plastic bags expanded polystyrene away from the reach of children Warning The system must not be used by people including children with reduced p...
Страница 4: ...necessary In the event of system malfunctions do not attempt to repair it Turn it off using the main switch unplug the plug and contact Customer service Make sure the power voltage matches the value i...
Страница 5: ...ain socket Warning Do not use solvents or abrasive detergents A damp soft cloth will suffice Cooler description JUMBO 13 is a remote cooler that refrigerates and carbonates water from the mains It is...
Страница 6: ...llowed without previous authorization by the owner Main components 1 Cold sparkling water 7 Tank water recirculation tubes 2 Cold still water 8 Identification plate 3 Still room temperature water 9 Po...
Страница 7: ...d electronic appliances must be disposed of separately from household waste and taken to authorized centers dedicated to the collection of special materials Package content After unpacking the cooler...
Страница 8: ...roduction allowed without previous authorization by the owner Installation Warning Professional installation is required Data on the power supply and water mains connections must meet the values indic...
Страница 9: ...g could restrict system performance Warning Safety devices must be adequately secured so as not to permit removal without adequate tools Warning Position the cooler away from heat sources Check minimu...
Страница 10: ...liquid sharp or hot objects or corrosive substances Warning Do not wind the power cord Warning Connect the cooler to the socket using the supplied power cord Connection to water mains Warning It is n...
Страница 11: ...connected to the reducer of the CO cylinder into the CO inlet of the cooler and slightly pull it to verify it holds correctly Use First start up Warning with the cooler switched off fill the internal...
Страница 12: ...riods of inactivity Regulate the pressure of water from the mains Warning When regulating pressure verify the new flow dispensing a small quantity of water For an optimum performance of the cooler reg...
Страница 13: ...to clean water coils properly Still water is immediately ready The ideal temperature for cold still and cold sparkling water will be reached after approximately 3 hours Adjustments Warning Periodicall...
Страница 14: ...Warning Do not use steel wool scrapers or abrasive acid or aggressive substances that could permanently damage the surfaces Cooler sanitizing with filter Warning Cooler sanitizing must be carried out...
Страница 15: ...not be held liable Warning Only use food safe CO cylinders Warning Do not touch the cooler with bare damp or wet hands or feet Warning Do not insert screwdrivers kitchen utensils or other utensils in...
Страница 16: ...water inlet tube is open and if water comes out of other taps If water is available and the water mains works properly proceed with Check of inlet water pressure If the water mains does not work prope...
Страница 17: ...ll a qualified technician Customer service Warning While waiting to solve a problem it is best not to use the cooler and disconnect it from the power mains unplugging it and from the water mains if th...
Страница 18: ...zed fan does not work Replace the motorized fan Compressor fault Replace the compressor Thermostat fault Replace the thermostat The motorized fan does not work No motorized fan power Check the electri...
Страница 19: ...box failure Replace level control box Frozen water in the coil Slightly lower the thermostat and wait When pressing the sparkling water button sprays of sparkling water come out Carbonation pump does...
Страница 20: ...BO 13 man rev 00 Manual of SODASTREAM Professional SRL Unipersonale No reproduction allowed without previous authorization by the owner Level control box failure Replace control box Pump blocked by li...
Страница 21: ...L Unipersonale No reproduction allowed without previous authorization by the owner JUMBO 13 wiring diagram MAIN SWITCH IMMERSION PUMP TANK AGITATOR TEMPERATURE REGULATING THERMOSTAT COMPRESSOR MOTOR F...
Страница 22: ...page 22 of 24 mod JUMBO 13 man rev 00 Manual of SODASTREAM Professional SRL Unipersonale No reproduction allowed without previous authorization by the owner JUMBO 13 hydraulic diagram...
Страница 23: ...10 Tavullia PU Italia DECLARES under its own responsibility that JUMBO 13 complies with the following Rules and Directives 2004 108 EC Electromagnetic Compatibility Directive 2006 95 EC Low Voltage Di...
Страница 24: ...Professional SRL Unipersonale No reproduction allowed without previous authorization by the owner www sodastreamprofessional it Sodastream Professional srl V Pirano 8 61010 Tavullia PU ITALY Telephon...