background image

NETYS RT

5 - 1 1   k V A

3 sec

1

72 DR

WNETR

T-XX

short

  Normal operation 

 

Normal drift

SWITCHING ON AND BATTERY CHARGING

Turn ON the Input switch on the back of the UPS 
module. The display is now active. 
Turn ON the battery switch on the back of the 
battery xtension module.

The batteries are now charging, and will be fully 
charged in approximately 8 hours.

PRESS - THE ON BUTTON UP TO BEEP

The LCD will display DIAGNOSTIC MODE, it will 
be a few seconds before the UPS commences 
normal operation.

The UPS can also be used with the batteries 
not fully charged, though if a power cut occurs 
backup time will be shorter.

The UPS may also be turned on with no mains 
power, using only the batteries as a power 
supply.

Be aware that if you do not press the on buttons 
for 3 seconds, the LCD will be active but with 
the UPS only on bypass mode and a yellow LED 
flashing. No battery backup is availible.

STARTE UPS OG LADE BATTERIER

På baksiden av UPS-kabinettet er det en 
inngangsbryter. Slå denne på, og skjermen blir 
aktiv. 
Slå på bryteren på baksiden av batterikabinettet.

Batteriene begynner nå å lades. La UPSen stå 
på lading i minimum 8 timer for å lade batteriene 
helt opp.

HOLD INNE PÅ-KNAPPEN TIL DU HØRER EN 
KORT PIPELYD

LCD-skjermen vil vise “DIAGNOSTIC MODE”, 
som tar noen sekunder før UPS er i normal drift. 

UPSen kan brukes selv om batteriene ikke 
er helt oppladet, men det vil medføre kortere 
batteribackuptid ved strømbrudd.

UPSen kan også slås på uten strømtilførsel, den 
bruker da de interne batteriene som strømkilde.

Dersom du ikke holder inne startknappen i 
3 sekunder, kan det virke som om UPSen er 
på. LCD-skjermen er aktiv, men UPSen er nå 
i bypass - gul LED lyser, og du vil ikke ha aktiv 
batteribackup.

MIMIC PANEL

A Display 
B  Red symbol - fault 
C   2 colour LCD - Green is Normal, RED - is 

overload

D  Green LED lit - normal operation
E  Power-on, Enter and Buzzer override button
F  Scroll button - UP
G  Scroll button - DOWN
H Off 

button

Green LED: Lit - Mains healthy, Flashing - 
Mains low but not lost

L  3 colour LEDs: Green - Battery power, Yellow 

- Battery low, Red - replace battery 

M  Yellow LED: Lit - Bypass mode, Flashing - 

Bypass voltage out of range

ENGLISH

NORWEGIAN

Den komplette manualen ligger på 
vedlagte CD-plate.

The full operating manual is on the CD 
ROM provided

Installasjon av UPS må tilfredsstille 
nasjonale retningslinjer. 

The UPS installation must comply with 
relevant national regulations. 

BATTERY MODE

The UPS automatically switches to battery 
mode when mains power fails. In this mode the 
Battery Mode LED indicator has a green light. 
Low battery level is indicated with a Yellow light in 
the battery symbol. Just before shutdown, when 
battery charge runs out fully, low battery charge 
is signalled via a rapid intermittent acoustic alarm.

The UPS automatically returns to normal 
operating mode about two seconds after the 
mains power is restored.

BATTERIDRIFT

UPSen vil automatisk bytte fra normal- til 
batteridrift dersom strømtilførselen svikter. I 
batteridrift vil LED-lampen i batterisymbolet lyse 
grønt. Lavt batterinivå signaliseres ved et gult lys 
i samme symbol. Like før UPSen slå seg helt av 
fordi batteriet tømmes, vil du høre en lydalarm 
hvert sekund.

UPSen vi automatisk returnere til normal drift 
etter to sekunder når strømtilførselen er normal 
igjen.

FORKLARING AV PANEL

A Skjerm
B  Rødt symbol lyser betyr feil på UPS
C   To farget LCD - Grønt betyr normalt, Rødt 

betyr overlast

D  Grønn LCD lyser betyr UPS i normal drift
E  Knapp for å slå på UPS, er også knapp for 

Enter eller slå av lyd

F  Velge menyer på LCD - skroller oppover
G  Velge menyer på LCD - skroller nedover
H AV-knapp

Grønn LED: Lyser betyr strømtilførsel OK, 
blinker betyr lav men ikke borte

L  3-farget LED: Grønt - UPS i batteridrift, Gul - 

lavt batterinivå, Rød - bytt batteri

M  Gul LED: Lyser - UPS i bypass, Blinker - I 

bypass, men dårlig strømkvalitet

110 DR

WNETR

T-XX

H

G

F

E

A

M

I

L

D

B

C

Battery 

mode 

   

Batteridrift

Connect the UPS to the mains, load and 
battery. The electrical installation must be 
performed by qualified technicians.

UPSen tilkobles nett, last og batteri. Dette 
skal utføres av autorisert elektriker.

Отзывы: