18
EN
COUNTIS E43/E44 - 547981A - SOCOMEC
10. USE
Switch menus by pressing "
". Press "
" to see the electrical readings or information within a menu.
The menus and related measurements are described in the table below:
Tariff 1
(Tar.1)
Tariff 2
(Tar.2)
Tariff 3
(Tar.3)
Tariff 4
(Tar.4)
Total (tot)
Partial
readings
and
energy
balance
(Par.b)
Realtime
values
(rt)
Informa-
tion (inFo)
Tariff 1 -
Imported
and exported
active energy
Tariff 2 -
Imported
and exported
active energy
Tariff 3 -
Imported
and exported
active energy
Tariff 4 -
Imported
and exported
active energy
Total imported
and exported
active energy
Partial
imported
active energy
by tariff
Active,
apparent
and reactive
power
Metrological
firmware
version
_________
_________
_________
_________
_________
_________
_________
_________
Tariff 1 -
Imported
and exported
inductive
reactive
energy
Tariff 2 -
Imported
and exported
inductive
reactive
energy
Tariff 3 -
Imported
and exported
inductive
reactive
energy
Tariff 4 -
Imported
and exported
inductive
reactive
energy
Total apparent
energy
Partial
imported
active energy
Phase/phase
and phase/
neutral
voltage
Non-
metrological
firmware
version
_________
_________
_________
_________
_________
_________
_________
_________
Tariff 1 -
Imported
and exported
capacitive
reactive
energy
Tariff 2 -
Imported
and exported
capacitive
reactive
energy
Tariff 3 -
Imported
and exported
capacitive
reactive
energy
Tariff 4 -
Imported
and exported
capacitive
reactive
energy
Total imported
and exported
inductive reac-
tive energy
Partial
exported
active energy
by tariff
Three-phase
current
Checksum of
metrological
firmware
_________
_________
_________
_________
_________
_________
_________
_________
Tariff 1 -
Imported
and exported
reactive
energy
Tariff 2 -
Imported
and exported
reactive
energy
Tariff 3 -
Imported
and exported
reactive
energy
Tariff 4 -
Imported
and exported
reactive
energy
Total imported
and exported
capaci-
tive reactive
energy
Partial
exported
active energy
Power factor
Checksum
of non-
metrological
firmware
_________
_________
_________
_________
_________
_________
_________
_________
Go back to
first screen,
menu "Tar.1"
Go back to
first screen,
menu "Tar.2"
Go back to
first screen,
menu "Tar.3"
Go back to
first screen,
menu "Tar.4"
Total imported
and exported
reactive
energy
Partial
apparent
energy
Frequency
Connection
type
_________
_________
_________
_________
Go back to
first screen,
menu "tot"
Partial
imported
and exported
reactive
energy
Go back to
first screen,
menu "rt"
Go back to
first screen,
menu "info"
_________
Active energy
balance
_________
Reactive en-
ergy balance
_________
Go back to
first screen,
menu "Par.b"