background image

M

ODEM

RS232 <=> RTC<=> RS485

Operating instructions

GB

SOCOMEC GROUP 

SWITCHING PROTECTION & UPS

MAKE YOUR BUSINESS SAFE

Содержание 4899 0200

Страница 1: ...MODEM RS232 RTC RS485 Operating instructions GB SOCOMEC GROUP SWITCHING PROTECTION UPS MAKE YOUR BUSINESS SAFE...

Страница 2: ...ions ____________7 Interface specifications ___________________________9 INSTALLATION __________________________________14 Connections___________________________________14 LED indicators _____________...

Страница 3: ...not open connected unit Hazardous voltage may occur within this unit when connected to power supply or TNV circuits CARE RECOMMENDATIONS Follow the care recommendations below to maintain full operati...

Страница 4: ...d users can commu nicate with the modem The modem is intended for mounting on a 35 mm DIN rail where the modem is attached and locked in a single action In the product there is also an RS485 interface...

Страница 5: ...These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Страница 6: ...RS232 RTC RS485 Modem 6 SOCOMEC R f 874 669 A GB APPROVALS AND CONFORMITY Declaration of conformity INTER 068 A GB...

Страница 7: ...80 AM 1 kHz 0 15 80 MHz Power frequency magnetic field EN 61000 4 8 Enclosure 100 A m 50 Hz 16 7 Hz 0 Hz Pulse magnetic field EN 61000 4 9 Enclosure 300 A m 6 4 16 s pulse Voltage dips and interruptio...

Страница 8: ...relative humidity non condensing Altitude Operating 2000 m 70 kPa Reliability prediction MTBF MIL HDBK 217F Operating Service life Operating 10 years Vibration IEC 60068 2 6 Operating 7 5 mm 5 8 Hz 2...

Страница 9: ...ection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 External supply current capability for proper startup POWER LV Rated voltage 12 to 48 VDC 12 to 27 V...

Страница 10: ...50 Hz 1 min Connection RJ 11C and Detachable screw terminal Connector size Detachable screw terminal 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required LEASED LINE LL Electrical specification 2 or 4 w...

Страница 11: ...ine 2 kVrms 50 Hz 1 min I O 1 5 kVrms 50 Hz 1 min Galvanic connection to RS232 Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 Miscellaneous Do...

Страница 12: ...terminal DCE Connector size Detachable screw terminal 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 Miscellaneous Do not connect RS232 and RS485 simultaneously 1 Railway installation close to th...

Страница 13: ...sure should be connected to the earthing system of an installation and may be directly connected to the protective earth GENERIC I O INTERFACE RELAY OUTPUT Electrical specification One change over con...

Страница 14: ...1 Direction relative to this unit 1 2 3 4 5 6 7 8 9 RS485 Position Direction 1 Description Product marking No 3 In Out T A A Tranmit Receive T RS485 2 wire No 4 In Out T A A Tranmit Receive T RS485 2...

Страница 15: ...set to always ON DTR OFF DTR signal is inactive Data carrier detect ON DTR signal is active REL OFF Reliable mode is OFF direct or normal mode Reliable mode ON Reliable mode is ON FLASH Reliable mode...

Страница 16: ...aud ON 1 2 3 4 5 6 7 8 19 2 bit s ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 38 4 bit s ON 1 2 3 4 5 6 7 8 2400 bit s ON 1 2 3 4 5 6 7 8 57 6 bit s ON 1 2 3 4 5 6 7 8 4800 bit s ON 1 2 3 4 5 6 7...

Страница 17: ...ON 1 2 3 4 5 6 7 8 RS485 enable RS232 disable RS485 ON 1 2 3 4 5 6 7 8 RS485 2 wire Leased Line 2 4 wire selection ON 1 2 3 4 5 6 7 8 Leased Line 2 wire ON 1 2 3 4 5 6 7 8 Leased Line 4 wire Selectio...

Страница 18: ...Line termination ON 1 2 3 4 5 6 7 8 Use stored value for AT Kn ON 1 2 3 4 5 6 7 8 RTS CTS flow control enable AT K3 Flow control DTE interface ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8...

Страница 19: ...2 3 4 5 6 7 8 V 34 33600 ON 1 2 3 4 5 6 7 8 Automatic line speed DIP switch settings S4 DIP SWITCH Selection of line speed and modulation ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8 Auto...

Страница 20: ...A20 DIRIS A40 COUNTIS Ci Max 0 3 metre T T T T A T T B 2 wire termination Termination recommendations The RS485 line must be terminated In the modem the termination is combined with fail safe functio...

Отзывы: