background image

Temperature measurement

Range

Resolution

Accuracy

-40°C to 1000°C

-40°C to 0°C

1°C

+ (3% + 5°C)

1°C to 250°C

+ (2% + 2°C)

-40°F to 1832°F

-40°F to 32°F

1°F

+ (3% + 5°F)

33.8°F to 482°F

+ (2% + 2°F)

Note: K type thermocouple probe (Ni-Cr and Ni-Si) is only applicable for the

measurement of temperature range -40°C to 250°C. Accuracy does not include

Type K thermocouple error.

General Specification

Power Supply

1 x 9V (6F22 / 6LR61 / 1604) battery

Low battery Indication

2.6 V appox

Overvoltage category

CAT III  1000V  (CAT IV 600V)

Operating Temperature

0 - 40ºC

Storage Temperature

-10 to 60ºC

Operating Humidity

80% @ 31ºC to 50% @ 40ºC

Safety Compliance

BSEN 61010-2-030:2010

EMC Compliance

BSEN 61326-2-2:2013

Test Leads

Dual insulated

Ceramic Fuses

1000V, F,600mA (Ø6x32mm)

1000V, F, 10A (Ø10x38mm)

Probes

GS38 Compliant

Dimensions (mm)

188 x 96 x 56

Weight (g)

415 Without battery

Содержание ENGINEER DMM

Страница 1: ...Instruction Manual Specification SAS095v1 ENGINEER DMM 6000 count true RMS digital multimeter...

Страница 2: ...test probes behind the finger guards Caution refer to the instruction manual Danger of electric shock Construction is double insulated Product should be recycled as electronic waste Conforms to EU st...

Страница 3: ...Digital Multimeter Test Leads 9v DF22 6LR61 1604 battery fitted K type temperature Ni Cr and Ni Si sensor temperature range measurable 40 C to 250 C Operating Manual 2 2 Features True RMS 6000 Count...

Страница 4: ...liampere AUTO Auto range Measurement A Microampere CAT IV Overvoltage category 4 A Ampere CAT III Overvoltage category 3 Negative Ground Potential Signal strength of NCV Over range H Freeze Hold readi...

Страница 5: ...f NCV Temp 6 MAX MIN MAX MIN button press once For recorded voltage current resistance and temp reading 7 REL relative reading button press once Adjust reading to zero except NCV range 8 Hold button...

Страница 6: ...mponent to be measured is safely isolated from any voltage source Turn the rotary switch to the resistance setting Ensure that the test leads are connected to the correct meter terminals Check the tes...

Страница 7: ...ent range required Ensure the test leads are connected to the correct meter terminals for the range selected Press the select button to choose AC or DC as required Connect the test probes in series wi...

Страница 8: ...ier and secure with the screws Fit rubber over mould 4 2 Trouble Shooting If required clean with a damp cloth and mild detergent Do not use abrasives or solvents With the exception of the batteries an...

Страница 9: ...0 15 5 digits DC Current A manual range Range Resolution Accuracy 600 0 A 000 1 A 0 12 3 digits 6000 A 1 A 0 12 3 digits AC Current mA manual range Range Resolution Accuracy 60 00mA 00 01mA 0 15 5 di...

Страница 10: ...cy does not include clamp meter error Resistance manual range Range Resolution Accuracy 600 0 000 1 0 7 5 digits 6 000K 0 001K 0 6 2 digits 60 00K 00 01K 0 6 2 digits 600 0K 000 1K 0 7 2 digits 6 000M...

Страница 11: ...de Type K thermocouple error General Specification Power Supply 1 x 9V 6F22 6LR61 1604 battery Low battery Indication 2 6 V appox Overvoltage category CAT III 1000V CAT IV 600V Operating Temperature 0...

Страница 12: ...CCHECK Calibration Checkbox SOC CB400 Non Trip Installation Testing Calibration Checkbox SOC VIP150 Craftsman Voltage Tester SOC SP400 Proving Unit SOC VVDPRO Vibrating Non Contact AC Voltage Detector...

Отзывы: