Troubleshooting
Model # SP-575V
Runs
Slow
One Speed
Vibrates
Material Free Flows
Does Not Stop
Material Does
Not Come Out
Material
Issue
Check Amp Draw
Bad Controller
Bent Shaft
Bent Spinner
Install Optional
Gate Kit (GAK-020)
Motor Runs Backwards
Correct Rotation
is Counter Clockwise
Physical
Obstruction
Must Be Dry, Clean
Free Flowing Material
Test 4 to 20 Amp Draw
No Load Good
20+ Amp Draw
No Load Bad
Replace Controller
Replace Transmission
Replace Spinner
Reverse Wires
At Motor
Clear Out
Obstruction
NOTE: Vibrator installed to assist material flow.
Snowex Diagnostic Test Kit (STK-090) Is Available To Accurately Diagnose Any Issues With Snowex Spreaders.
Call Your Dealer For Details.