Snorkel S3219E Скачать руководство пользователя страница 5

S3219E/S3220E/S3226E/S4726E/S4732E – 1500842 

Warning

All personnel shall carefully read, understand and follow all safety rules and operating instructions 

before operating or performing maintenance on any Snorkel aerial work platform.

Electrocution Hazard

Tip Over Hazard

Collision Hazard

Fall Hazard

THIS MACHINE IS 

NOT INSULATED!

NEVER

 elevate the platform 

or  drive  the  machine  while 

elevated unless the machine 

is on a firm, level surface.

NEVER

 position the platform 

without  first  checking  for 

overhead  obstructions  or 

other hazards.

NEVER

 climb, stand, or sit 

on  platform  guardrails  or 

midrail.

USE OF THE AERIAL WORK PLATFORM:

 This aerial work platform is intended to lift persons, their tools and materials 

used for the job. It is designed for repair, assembly, stockpicking jobs, etc., and assignments at workplaces above head height 

(ceilings, cranes, roof structures, buildings, shelving, etc.). All other uses of the aerial work platform are prohibited and the 

rules below must be adhered to!

THIS AERIAL WORK PLATFORM IS NOT INSULATED! 

Refer to applicable national standards for safe approach distances.

is prohibited! 

See “Platform Capacity” on page 6 for details.

The use and operation of the aerial work platform as a lifting tool or a crane 

is prohibited!

NEVER 

exceed the manual force allowed for this machine. See “Manual Force” on page 6 for details.

DISTRIBUTE 

all platform loads evenly on the platform.

NEVER 

or debris; and avoiding them.

OPERATE 

machine only on surfaces capable of supporting wheel loads.

NEVER 

operate the machine when wind speeds exceed this machine’s wind rating. See “Beaufort Scale” on page 7 for details.

Do not operate the aerial platform in windy or gusty conditions. Do not add anything to or take anything into the aerial platform 

that will increase the wind loading such as billboards, banners, flags, etc.

IN CASE OF EMERGENCY 

push EMERGENCY STOP switch to deactivate all powered functions.

IF ALARM SOUNDS 

Climbing up the railing of the platform, standing on or stepping from the platform onto buildings, steel or prefab concrete 

structures, etc., 

is prohibited!

Dismantling the entry gate or other railing components 

is prohibited! 

Always make certain that the entry gate is closed!

It is prohibited 

to keep the entry gate in an open position when the platform is raised!

To extend the height or the range by placing of ladders, scaffolds or similar devices on the platform 

is prohibited!

NEVER 

perform service on machine while platform is elevated without blocking elevating assembly.

INSPECT 

the machine thoroughly for cracked welds, loose or missing hardware, hydraulic leaks, loose wire connections, and 

damaged cables or hoses before using.

VERIFY 

that all labels are in place and legible before using.

NEVER 

use a machine that is damaged, not functioning properly, or has damaged or missing labels.

To bypass any safety equipment 

is prohibited 

and presents a danger for the persons on the aerial work platform and in its 

working range.

NEVER 

are prohibited 

or permissible only at the approval by 

Snorkel

.

AFTER USE

, secure the work platform from unauthorized use by turning the keyswitch off and removing key.

Certain inherent risks remain in the operation of this machine despite utilizing proper design practices and safeguarding. 
Care must be taken to ensure that the machines meets the requirements of stability during use, transportation, assembly, 

dismantling when out of service, testing, or foreseeable breakdowns.
In the event of an accident or breakdown see “Emergency Lowering” on page 15, do not operate the aerial platform if it is 

platform back into service.

SAFETY RULES

Содержание S3219E

Страница 1: ......

Страница 2: ......

Страница 3: ...ve Range Switch S3226E S3220E S4726E S4736E 10 Horn Button 10 Battery Condition Indicator 10 Pre Operation Safety Inspection 10 System Function Inspection 11 Operation 12 Preparing for Operation 12 Lo...

Страница 4: ...cate number EC Typenprufung Zertifikat Nr Examen type CE Numero de Certificat Inspeccion tipo CE Numero de certificado Attestato di certificazione CE nr Onderzoek van het type EC Certificaatnummer EU...

Страница 5: ...anything to or take anything into the aerial platform that will increase the wind loading such as billboards banners flags etc IN CASE OF EMERGENCY push EMERGENCY STOP switch to deactivate all powere...

Страница 6: ...ont View Front View Anchor point Type 1 is rated for one lanyard attachment per loop Refer to machine Specifica tions and platform decals for maximum number of platform occupants Two Lanyards Attached...

Страница 7: ...so stamped on the front of the chassis Scissors Structure Right Side Platform Guardrails Left Side Chassis Upper Controls Entry Doors Platform Extension Battery Tray Drive and Steer Wheels Pothole Pro...

Страница 8: ...Refer to the machine specifications for the level sensor factory setting Lower the platform and drive to a level surface when the drive lift level sensor alarm sounds The drive lift level sensor syste...

Страница 9: ...small branches sway 5 8 0 10 8 28 8 38 9 26 25 35 5 18 24 25 Shrubs with leaves start swaying Wave crests are apparent in ponds or swamps 6 10 8 13 9 38 9 50 0 35 5 45 5 24 5 31 umbrella 7 13 9 17 2 5...

Страница 10: ...The diagnostic center LCD display is located in the hy draulic tray next to the fluid reservoir refer to Figure 4 Upper Controls Top Upper Controls Front 13 7 8 9 10 12 11 Controls and Indicators The...

Страница 11: ...platform functions will not operate from the lower or upper controls Turn the switch to the upper controls position to operate the aerial platform functions from the upper controls Hold the switch do...

Страница 12: ...ch controls the two front wheels to steer the aerial platform To steer to the right engage the interlock switch on the joystick and hold down the right side of the steer switch To steer to the left en...

Страница 13: ...welds and structural damage loose hardware hydraulic leaks loose wire connec tions and erratic operation Check for missing or loose parts 5 Hold the ground operation switch downward Test each machine...

Страница 14: ...edure to prepare the aerial platform for operation 1 Perform a pre operation safety and system function inspection 2 Close and latch the control valve hydraulic and bat tery trays 3 Place the battery...

Страница 15: ...will flash In this case remove the load in excess of rated capacity and cycle the emergency stop button at the upper controls to return to normal operation Extending The platform can be extended and s...

Страница 16: ...2 4 m 8 and up to 0 6 km h 0 4 mph when the platformis raisedabove 2 4 m 8 Place the drive range switch in high for normal machine operation Caution The extension deck is free to move when the exten s...