Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 173
© 2017 SAM
Connecting to Nucleus/2460/Nebula/Aurora
Connection to Other Equipment 9.6
9.6.1 RS 422 Connection
9.6.1.1
Vega-MV Settings
•
Configure serial port as RS422 (see section 9.1 for jumper settings).
•
Configure serial port details
(Setup Module > Protocols Tab > Serial Ports Tab > Configure)
9.6.1.2
Vega-MV Wiring Connections to Nucleus/2460/Nebula/Aurora Controller
The cable wiring connections for Nucleus/2460/Nebula/Aurora are shown in Figure 135
9.6.1.3
Nucleus Settings
Changes made to the Nucleus router control module database configuration must be pushed
from Workbench to the router controller to make the controller use the new configuration. In a
dual controller router changes must be copied to the second controller and the database must
be pushed to both controllers (idle controller first, see the router manual for full details).
Nucleus2 2464/2463/2460
:
•
Use Workbench to configure the Nucleus2 2464/2463/2460 serial port.
(Routers > Port Configuration button > New Serial Port button)
Baud Rate
Data Bits
Parity
Stop Bit
Flow Control
Protocol
38400
8
None
1
None
Snell Router
Table 62
Vega-MV Serial Port Settings.
Note:
•
The connections shown in Figure 135 are not pin to pin.
Figure 135 Vega-MV Connections to Nucleus/2460/Nebula/Aurora Controller
GND 1
RX- 2
TX- 3
4
5
1
2 TX-
3 RX+
4 0V
5
6
RX+ 7
TX+ 8
9
6
7 TX+
8 RX-
9
1
5
9
6
Vega-MV RS232/RS422
connector configured as RS 422
Nucleus/2460/Nebula/Aurora
RS485 Pin-outs
1
5
9
6
Connections are not pin to pin
Baud Rate
Data Bits
Parity
Stop Bit
Flow Control
Protocol
38400
8
None
1
None
General
Remote In
(SW-P-08)
Table 63
Nucleus2 2464/2463/2460 Serial Port Configuration